MicroGuard 511 Retrofit
4
W450512 03/08
Display Console
TEST
SET
MAX
1
5
6 7
8 9 10
11
12
2
3
4
Overload Warning – This red LED illuminates when you reach or exceed 100% of rated
1.
capacity. It is accompanied by continuous audible alarm.
Approaching Overload Warning – This amber LED Illuminates when you reach or exceed 90%
2.
Rated Capacity. It is accompanied by an intermittent audible alarm.
Parts of Line – Displays current number of parts of line in use.
3.
Load on Hook – Displays the entire hook load weight under the head of the boom, including
4.
cable, load block, load handling equipment, and weight of load hanging on hook.
Percent of Rated Capacity Meter - Shows the load as a percentage of rated capacity. As the
5.
load increases, the meter level increases to represent the percentage of the rated capacity of
the crane.
Rated Capacity – Displays the rated capacity in the current configuration based on the crane
6.
load capacity chart.
ATB Warning – Warns of a potential two-block condition with flashing LED and audible alarm.
7.
Boom Length – Displays the current boom length in feet and tenths of a foot.
8.
Boom Angle – Displays the current boom angle in degrees and tenths of a degree.
9.
Load Radius – Displays the load radius from centerline of rotation.
10.
Crane Setup – These keys are used in the setup process to configure the system to match
11.
the current configuration of the crane.
Information Window – Displays crane setup and calibration information as well as warning
12.
messages.