MicroGuard 511 Retrofit
16
W450512 03/08
To set a new working area, you must first reset
the left and right points. Press the keys adjacent
to “Left Point” and “Right Point” so they show
“off”.
Rotate the boom to the left point. This is the
point to the left facing the exclusion zone to be
defined.
Press the key adjacent to “Left Point”.
Rotate the boom to the left until the right point
is reached (this will avoid having to pass through
the exclusion zone). This is the point to the right
facing the exclusion zone to be defined.
Press the key adjacent to “Right Point”.
To deactivate the swing alarms, press the
operaTor alarm
key twice. Press the key
adjacent to “Left Point XX.X” and “Right Point
XX.X” so they show “Left Point Off” and “Right
Point Off”.
m
WARNING
FAILURE TO DEACTIVATE BOTH ALARMS WILL RESULT IN A CONTINUOUS AUDIBLE ALARM.
BOTH LEFT AND RIGHT SWING ALARMS MUST BE SET OR OFF TO FUNCTION PROPERLY.
TEST
SET
MAX
TEST
SET
MAX
TEST
SET
MAX