MicroGuard 511 Retrofit
5
W450512 03/08
TEST
SET
MAX
14 15
13
16
Erected Jib – Enables the selection of the jib to be used on the boom. Selects extended or
13.
retracted jib when crane is equipped with two stage jib.
Auxiliary Head - Enables the attachment of the auxiliary head.
14.
Outrigger Configuration – Enables the selection between full and mid span outriggers.
15.
Stowed Jib – Enables the selection of the jib stowed on the boom. Also used to stow the
16.
erected jib.
Winch Selection – Enables the selection of the winch if the crane is equipped with an optional
17.
second winch.
Test Button – Press and hold the test button to initiate a system self test and run diagnostics.
18.
Alarm Set Button – Enables operator settable alarms. When an alarm has been set, the LED
19.
above this button will illuminate yellow.
m
WARNING
YOU MUST USE THE CRANE SETUP MODE TO CORRECTLY SET THE SYSTEM FOR PROPER
OPERATION. THE SYSTEM SETUP MUST MATCH THE ACTUAL CONFIGURATION OF THE CRANE
SO THAT IT WILL INDICATE THE CORRECT HOOK LOAD AND LIFTING CAPACITY OF THE CRANE.