CAUTION
When placing battery pack in the blower, be sure the
raised ribs on the battery pack align with the grooves
in the top of the blower. Make sure the battery is fully
seated, and it latches into place properly. Improper
installation of the battery pack can cause damage to
internal components.
TO REMOVE BATTERY PACK
See Figure 5.
pack.
STARTING/STOPPING THE BLOWER/MULCHER
See
Figures 6.
1. Press the On/Off (
) Switch and you will hear
beeping sounds, and the blower will turn on in low
speed.
2. Roll the variable speed dial forward to increase speed
from 110km/h to 210km/h
3. Press the low/high switch (
) to increase the
speed options from 130km/h to 280km/h.
4. To Turn off, press the on/off switch (
)
IMPORTANT: TURBO-MULCH by pressing the “LOW
HIGH button, with the variable speed dial set to high
speed.
HOLDING THE BLOWER/MULCHER
See Figures 7.
Before operating the unit, stand in the operating position.
Check for the following:
safety glasses or goggles, ear/hearing protection,
gloves, long pants and a long sleeve shirt.
WARNING
To avoid serious personal injury, wear goggles or
safety glasses at all times when operating this unit.
Wear a face mask or dust mask in dusty locations.
WARNING
To prevent serious personal injury or damage to the
unit, make sure the blower tube or the mulcher tubes
and the bag are in place before operating the unit.
OPERATING TIPS
See Figure 8.
a mulcher).
unit.
loose debris before starting the unit.
sure the tubes and guards are in place and secure.
grips.
sound level(s), hearing protection is required.
not early in the morning or late at night when people
might be disturbed. Comply with times listed in local
ordinances. Usual recommendations are 9:00 am to
STATUS
LED
S O L V E
METHOD
hall fault
protection
Green light off red
light on; flash 7
times; each time
keep 1hz interval:
3s; keep 60s
buzzer alarm
Off the trigger and
restart it
low-voltage
protection
Green light off red
light on; flash 5
times; each time
keep 1hz interval:
3s; keep 60s
buzzer alarm
Off the trigger and
restart it or
Charging the
battery
Over load
protection
Green light off red
light on; flash 4
times; each time
keep 1hz interval:
3s; keep 60s
buzzer alarm
Off the trigger and
restart it
Battery jam
protection
Green/Red light
off; Unit stop
running
Resetting the
blower vac by
removing the
battery for 5
seconds
Abnormal
battery
temp
Led off
When the temp. of
the battery low
down, the blower
can run well
English (original instructions)
EN
DE ES IT FR PT NL RU FI SV NO DA PL CS SK SL HR HU RO BG EL AR TR HE LT LV ET
2
Содержание 24227
Страница 38: ...RU EN DE ES IT FR PT NL FI SV NO DA PL CS SK SL HR HU RO BG EL AR TR HE LT LV ET 37 ...
Страница 39: ...RU EN DE ES IT FR PT NL FI SV NO DA PL CS SK SL HR HU RO BG EL AR TR HE LT LV ET 38 ...
Страница 40: ...RU EN DE ES IT FR PT NL FI SV NO DA PL CS SK SL HR HU RO BG EL AR TR HE LT LV ET 39 ...
Страница 41: ...RU EN DE ES IT FR PT NL FI SV NO DA PL CS SK SL HR HU RO BG EL AR TR HE LT LV ET 40 ...
Страница 94: ...tub 93 HU HR SL SK CS PL EN DE ES IT FR PT NL RU FI SV NO DA RO BG EL AR TR HE LT LV ET ...
Страница 121: ...LT HE TR AR EL BG RO HU HR SL SK CS PL EN DE ES IT FR PT NL RU FI SV NO DA LV ET Veids 24227 4 kg 120 ...