11
1. Continous
When the selector switch is in the CONT position the ventilation system will exhaust
stale indoor air to the outside and will introduce fresh outdoor air continuously on low
speed except when there is a request for ventilation by one of the remote controllers
then the ventilation system will exchange at high speed.
(Recommended for maximum
indoor air quality.)
9. MODES OF OPERATIONS
Fresh air to
dwelling
Stale air to
outside
Fresh air from
outside
Stale air from
dwelling
Stale air to
outside
Stale air from
dwelling
Normal
Evacuation
DEFROST CYCLE TYPES:
Defrost sequence type: Evacuation (Ref. Supply fan shut down)
An automatic defrost sequence is activated at an outdoor measured temperature of
-5°C (23°F) and colder.
During the electronically controlled defrost sequence, the supply motor (incoming air)
shuts down while the exhaust motor continues to run to exhaust distribute warm
ambient air through the core. This eliminates the risk of the ERV core from building up
with ice and freezes.
Содержание LCH-12E
Страница 14: ...14 LOW SPEEDS 90V 75V J4 J5 J6 12 WIRING DIAGRAM LCH 4E...
Страница 15: ...15 LOW SPEEDS 90V 75V J4 J5 J6 13 WIRING DIAGRAM LCH 7E...
Страница 16: ...16 LOW SPEEDS 90V 75V J4 J5 J6 14 WIRING DIAGRAM LCH 12E...
Страница 18: ...50 Kanalflakt Way Bouctouche NB E4S 3M5 1 888 724 5211 Fax 1 866 426 7430 www greentek ca Item 444863...
Страница 32: ...32 12 SCH MA DE C BLAGE LCH 4E LOW SPEEDS 90V 75V J4 J5 J6...
Страница 33: ...33 13 SCH MA DE C BLAGE LCH 7E LOW SPEEDS 90V 75V J4 J5 J6...
Страница 34: ...34 14 SCH MA DE C BLAGE LCH 12E LOW SPEEDS 90V 75V J4 J5 J6...
Страница 36: ...50 Kanalflakt Way Bouctouche NB E4S 3M5 1 888 724 5211 Fax 1 866 426 7430 www greentek ca Item 444863...