www.greenoks.com.tr
[EN]
6
The gas and electricity connections of the appliance must be made in accordance with the
manual and electrical diagram given in this manual.
The manufacturer accepts no liability for any damage caused to humans or property due
to maintenance or technical interventions not performed by authorized technicians, from any
operation performed without the guidance.
Things to do before installation
Please note that before installation, the following are true and complete. If it is not possible
to install due to a failure due to any of the following; the road and hour charge will be requested
from the customer.
•
Plumbing belongs to the customer.
Elektrik veya gaz ile çalışan cihazların tesisatın
çekilmesi müşteriye aittir.
•
The earth line must be found in the electrical wiring to be towed.
•
The installation should be brought to the point where it is used.
•
If the electrical ovens will be connected to the switch;plug-in phases must be observed
absolutely.
•
Working pressure must be observed on gas operated ovens. It is mentioned in the T2
Table.
•
In electrical ovens worked by 380 V; The electrical connection must be made by a
specialist service members, otherwise your device is not covered by the warranty.
•
On gas powered Ovens; The gas connection must be made by a specialist service
memebers, otherwise your device is not covered by the warranty.
•
This information should not be left out, otherwise the oven will be out of warranty.
Electrical Connection
•
The oven must be connected to the network in accordance with DIN, VDE 0100
electrical installation standards.
•
Supply the oven with the operating voltage and frequency specified in the Table T2.
•
Use cable of quality H07 RN-F for the electric panel connection line. The cable cross
section to be used is indicated in the T2 Table.
•
Voltage tolerance must not /- 10%.
•
The oven must not be operated until the ground connection is made.
•
Automatic fuse must be fitted to the input line of the oven at the value specified in
the T2 Table.
•
Our company is not responsible for problems caused by frequent interruption of mains
voltage and irregular voltage changes.
Water Connection
•
A tap must be connected between the water inlet of the oven and the main network.
•
The oven water inlet R 3/4 "exits from the factory as a male.
•
The water connection of the device should be done with a hose with R 3/4 "thread.
•
A mechanical filter must be installed in the water inlet of the device and any dirt or
metal particles that may enter the device must be filtered.
•
Before the last pipe part is connected to the oven, some water should be drained from
the pipe and the dirt inside should be thrown out.
•
Check for water leaks at the connection points.
The inlet water pressure should be between 1.5 ~ 2.5 bar.