FumeJet

®

 Fume Exhaust Fans

4

®

Guards – Motor Cover, Weatherhood

Do not operate fans without proper protective devices in 
place. Failure to do so may result in serious bodily injury 
and property damage. Check local codes to ensure 
compliance for all protective devices.

Access Doors

Before opening access doors, ensure the fan wheel has 
stopped moving and that the wheel has been secured 
from being able to rotate. Do not operate fan without 
access door in its fully closed position.

Air Pressure and Suction

In addition to the usual hazards associated with rotating 
machinery, fans also create a dangerous suction at the 
inlet. Special caution needs to be used when moving 
around a fan, whether it is in operation or not. Before 
start-up, make sure the inlet area is clear of personnel 
and loose objects.

To ensure a successful installation, the instructions in 
this manual should be read and adhered to. Failure to 
comply with proper installation procedures may void the 
warranty.

Unit and System Identification Tags

Each fan has a permanently affixed manufacturer’s 
engraved metal nameplate containing the model 
number and individual serial number.

The tag shown 
is an example of 
an identification 
nameplate on the 
fan. The information 
provides general 
details about the fan, 
as well as containing specific information unique to 
the unit. When contacting your local manufacturer’s 
representative with future needs or questions, please 
have the information on this label available. Tags are 
mounted in an area which is clearly visible, usually on 
the side of the fan cabinet.

Pre-Installation Information

Before installation, it is important to be certain the 
mounting surface will bear the operating weight of the 
unit. For proper unit operation, it is also important that it 
be operated in a completely level position.

For further details on safety practices involving 
industrial and commercial fans, please refer to AMCA 
Publication 410.

Electrical Disconnects

All fan motors should have disconnects located in close 
visual proximity to turn off electrical service. Service 
disconnects shall be locked-out when maintenance is 
being performed.

Moving Parts

All moving parts must have guards to protect personnel. 
Refer to local codes for requirements as to the number, 
type and design. Fully secure fan wheel before 
performing any maintenance. The fan wheel may start 
“free wheeling” even if all electrical power has been 
disconnected. Before the initial start-up or any restart, 
check the following items to make sure that they are 
installed and secure.

•  Do not spin fan wheel faster than the maximum 

cataloged fan RPM.

•  Adjustments to fan speed significantly affects motor 

load. If the fan RPM is changed, the motor current 
should be checked to make sure it is not exceeding 
the motor nameplate amps.

General Information

Содержание FumeJet FJC-300

Страница 1: ...peut tre suffisamment chaud pour provoquer une douleur voire une blessure Laisser le moteur refroidir avant toute maintenance ATTENTION Faire preuve de pr caution dans les atmosph res explosives FJC 3...

Страница 2: ...phere which is sealed to prevent the entry of blowing dust rain or snow Temperatures should be evenly maintained between 30 to 110 F 1 to 43 C wide temperature swings may cause condensation and sweati...

Страница 3: ...m Storage 3 General Information Unit and System Identification Tags 4 Pre Installation Information 4 Electrical Disconnects 4 Moving Parts 4 Guards Motor Cover Weatherhood 4 Access Doors 4 Air Pressur...

Страница 4: ...ormation unique to the unit When contacting your local manufacturer s representative with future needs or questions please have the information on this label available Tags are mounted in an area whic...

Страница 5: ...t Installations Inlet Duct Turns Installation of a duct turn or elbow too close to the fan inlet reduces fan performance because air is loaded unevenly into the fan wheel To achieve full fan performan...

Страница 6: ...coating repair section of this manual for details involving touch up of damaged surfaces Lift unit before mounting the stack to the fan body Use standard lifting and rigging practices ALL lifting bra...

Страница 7: ...illustrate three common methods used to install roof curbs for FumeJet systems Methods used to attach a unit are dependent on local codes roof construction design and roof construction materials Consu...

Страница 8: ...installation of the duct drop Duct support will be supplied with roof curb from fan manufacturer or by others Duct Drop and Connection by others Duct Spacing FJC 300 FJI Duct Support inches mm 306 11...

Страница 9: ...ons with application appropriate sealant or tape Stack Installation NOTE Fans should never be lifted by the shaft motor motor cover or accessories Equipment Supports Model GESS equipment supports are...

Страница 10: ...closed Any increase in fan speed represents a substantial increase in load on the motor To avoid motor overheating and possible burnout motor load amperes should always be checked and compared to nam...

Страница 11: ...ening the inlet cone ring bolts and centering the cone ring on the wheel If additional adjustment is required to maintain a constant radial gap loosening the bearing bolts and centering the wheel is a...

Страница 12: ...for colors other than our standard TOUCH UP PAINT REPAIR KIT CONTENTS One pint of Kem Kromik primer including a technical data sheet One pint of industrial enamel including a technical data sheet Four...

Страница 13: ...ere the motor will run in either direction depending on how it has been wired To reverse rotation of a 3 phase motor interchange any two of the three electrical leads Single phase motors can be revers...

Страница 14: ...easing the upper limiting frequency Always check the fan rpm when adjusting the operating frequency Do not exceed maximum class fan rpm of the wheel Belt Span De ection Belt Span 64 Once the unit has...

Страница 15: ...ing to NLGI Grade 2 Factory recommends Mobilux EP 2 The use of synthetic lubricants will increase lubrication intervals by approximately 3 times In addition to lubricating the bearings at speci ed int...

Страница 16: ...cturers procedures for removal and installation 3 Before removing the bearing bolts make sure the shaft is supported slightly Remember to consider the wheel weight on the shaft 4 Remove both bearings...

Страница 17: ...make certain unit is not capable of operation during repairs CAUTION La pr sence d un moteur antid flagrant sur un ventilateur ne garantit pas que tout l appareil est antid flagrant Pour conna tre les...

Страница 18: ...ith optional curb cap inlet box and inlet flanges Stack Motor Cover Disconnect Switch Motor Plate Motor Integrated Mounting Rails Access Door Curb Cap Isolation Damper Roof Curb Scroll Housing Inlet C...

Страница 19: ...s in system Use correction factor to adjust for temperature altitude Resize ductwork Clean lters coils Change fan speed High Motor Amp Draw Fan Check rotation of wheel Reduce fan speed Duct System Res...

Страница 20: ..._____ AM PM Notes __________________________________________ ________________________________________________ ________________________________________________ _________________________________________...

Отзывы: