12
Wire material
type
Total length of
communication
line between
indoor unit and
wired controller
L (m/feet)
Wire size
(mm
2
/AWG)
Material
standard
Remarks
Light/
Ordinary
Polyvinyl
chloride
sheathed cord.
(60227 IEC 52
/60227 IEC 53)
L≤250m
(L≤820
-1/5feet)
2×0.75
mm
2
~2×
1.25 mm
2
(2×AWG18~
2×AWG16)
IEC
60227-5:2007
(1) Total length of
communication line
can't exceed 250m
(820-1/5feet).
(2) The cord shall be
Circular cord (the cores
shall be twisted
together).
(3) If unit is installed in
places with intense
magnetic field or strong
interference, it is
necessary to use
shielded wire.
NOTES:
①
If the air conditioner is installed in the place with heavy magnetic field, the
wired controller must adopt shielded twisted pair.
②
Communication wire material of wired controller must meet the
requirements of this instruction manual. It is not allowed to use the
communication wire not in consistent with the requirements of this
instruction manual.