Wired Controller XE70-33/H
39
mode, when the temperature is 16
℃
, press the “
” button twice can decrease the
temperature to 12
℃
(when the heating Save function is activated, the Dry
temperature should not be adjusted to 12
℃
, the range is “lower limit value of Save
temperature” ~30
℃
).
NOTES:
①
When the Absence function is activated, the set temperature should not be
adjusted via “
” or “
” button.
②
Under Auto mode, it cannot enter into temperature setting interface, user can
only set the cooling and heating temperature of Auto mode in the project
parameters setting page.
③
When the wired controller connects to Fresh air IDU, the homepage will not
display the set temperature, while the temperature displaying area will
display the code of Fresh air IDU “FAP”, and the temperature setting
interface cannot be accessed, user can only set the cooling or heating
air-out temperature in the parameter setting page.
7.4 Setting of Fan Speed
Under ON status, pressing " " button on homepage can switch fan speed
circularly in the following order:
Auto->Low->Med. Low->Medium-> Med. High ->High-> Auto