122
Disassembly of Outdoor Unit
18,000 and 24,000 btuh
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
8. Remove the 4 way valve assembly
9. Remove compressor
1. Remove the screws holding the 4-way valve coil.
Properly remove refrigerant, protect valve from heat
damage and remove valve.
2. Unsolder the tubing connecting the compressor and
condenser assembly, then remove the 4-way valve.
1. Remove the three foot nuts on compressor, then
carefully remove the compressor.
All manuals and user guides at all-guides.com
Содержание RIO09HP115V1A
Страница 41: ...41 Electrical Schematics 24K Indoor Unit All manuals and user guides at all guides com a l l g u i d e s c o m ...
Страница 42: ...42 Electrical Schematics 24K Indoor Unit All manuals and user guides at all guides com ...
Страница 130: ...130 Gree Electric Appliances Inc C 2014 Cat No DFS RIO HP 2SM All manuals and user guides at all guides com ...