background image

Table of Contents

Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Safety Precautions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4

Part Names  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

System Functions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8

Operation of Wireless Remote Contoller  . . . . . . . . . . . . . . . . . . 9 -16

Care and Cleaning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-19

Energy Saving Tips  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back

Thank you for choosing a

Livo Heat Pump System!

You can feel confident in your selection because the same pride in craftsmanship
and engineering knowledge that goes into millions of other Gree installed 
products worldwide has gone into your unit.

Please read this owner’s manual carefully before operation and retain it for 
future reference.

ENERGY SAVING TIPS

1.  Reduce room setpoint at night:

During the nighttime hours you don't require the

same level of conscious cooling or heating. Try using Sleep Mode to gradually relax
room temperature and allow the unit to run less and save energy.

2.  Curtains and shades:

In the summer, it is recommended to block the effects of the

sun. Close window curtains and shades on the south and west side of your home to
help block solar heat. In winter, the sun is your friend. Open curtains and shades to
allow solar heat into your room.

3.  Close doors:

If you don’t need to heat and cool your whole home, confine the heat-

ing and cooling to one room by closing doors. 

4.  Service the unit:

Some basic maintenance might be all you need. The outdoor unit

will greatly benefit from a good hosing off, especially in treed areas where seeds and
other debris can stick to coil fins and make the unit work up to 15% harder!

5.  Rearrange the room:

Furniture that obstructs airflow means you could be heating

and cooling the back of a chair instead of the actual living space. Remove or rearrange
obstacles blocking airflow.

6.  Try 75 degrees:

75°F is a good point for an air conditioner to run at its optimal 

performance level. Even a 5-degree change in temperature can make your unit use 
up to 40% more energy.

7.  Lighting:

Turning lights off can help reduce your heat. Each light bulb is a tiny heater.

Your air conditioner must waste energy overcoming the heat from your lights to reach
and hold your desired room temperature.

8.  Is anyone home?

If possible, while you're away turn your unit to Auto mode and

make sure windows and curtains are closed. Although room temperature may be less 
than optimal for a few minutes when you return, the unit will soon have the room 
back to your desired temperature.

9.  Don't forget the fan:

The fan is much like a car. The faster it runs, the more energy it

uses. Sometimes we need the car to go fast, but slow is good enough most of the time.
Try saving money by using the comfortable quiet low fan speed as much as possible.

TWD-1594 Livo+ owners printer.qxp_Layout 1  2/21/17  2:10 PM  Page 5

2

1

Содержание livo GEN 3 LIVV09HP230V1A

Страница 1: ...P230V1A LIVV18HP230V1A LIVV30HP230V1A LIVV12HP230V1A LIVV24HP230V1A LIVV36HP230V1A HIGH WALL DUCTLESS AIR CONDITIONING HEATING SYSTEM OWNER S MANUAL TWD 1594 Livo owners printer qxp_Layout 1 2 21 17 2...

Страница 2: ...maintenance might be all you need The outdoor unit will greatly benefit from a good hosing off especially in treed areas where seeds and other debris can stick to coil fins and make the unit work up...

Страница 3: ...ust be removed to allow continuous drainage by gravity If problem persists contact a qualified service professional for assistance Cause There are a number of possible reasons Solution Check the follo...

Страница 4: ...unit is not heating or cooling adequately Water leakage from the outdoor unit CAUSE SOLUTION Cause The system has a built in three minute delay to prevent short and or rapid cycling of the compressor...

Страница 5: ...unit It is recommended that air filters be cleaned every three 3 months To access and clean the filter CARE AND CLEANING Take notice of the following items before cleaning your Livo indoor wall unit T...

Страница 6: ...polarity Reattach back cover NOTE If the remote controller will not be used for a long time remove batteries to prevent leakage damage Be sure to aim the remote controller at the receiver of the main...

Страница 7: ...desired room temperature in the shortest possible time This mode runs the unit at ultra high speeds for quickest results FREEZE GUARD Room Freeze Guard protection will automatically keep the room tem...

Страница 8: ...m will automatically return to the last operating mode INTELLIGENT DEFROST The Liv Intelligent Defrost function increases room comfort and saves energy by eliminating unnecessary defrost cycles In hea...

Страница 9: ...he word ON blinking Press or buttons to adjust timer setting 1 minute at a time Press and hold or button to set timer more quickly Press Timer ON Timer OFF button again to confirm setting and the word...

Страница 10: ...ng in cooling mode with low fan speed 2 If the RoomTemperature is between 4 F higher than and 4 F less than the set temperature the system will cycle 6 minutes ON and 4 minutes OFF in cooling mode The...

Страница 11: ...ignal has been sent to the air conditioner Under off status set temperature and clock icon will be displayed on the display of remote controller If timer on timer off and light functions are set the c...

Страница 12: ...n indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould Having set X FAN function on After turning off the unit by pressing ON OFF button indoor...

Страница 13: ...n again to exit turbo function and icon will disappear button 6 Press or button once increase or decrease set temperature 1 1 F Holding or button 2s later set temperature on remote controller will cha...

Страница 14: ...ater time will change quickly Release this button when reaching your required time Note Clock time adopts 24 hour mode The interval between two operations can t exceeds 5s Otherwise remote contro ller...

Страница 15: ...el it Function introduction for combination buttons Energy saving function Under cooling mode press TEMP and CLOCK buttons simultaneously to start up or turn off energy saving function When energy sav...

Страница 16: ...function will cancel sleep function Temperature display switchover function I FEEL Function Under OFF status press and MODE buttons simultaneously to switch temp erature display between and Press and...

Страница 17: ...ller will automatically adjust the indoor temperature according to the detected tempera OPERATION OF WIRELESS REMOTE CONTROLLER CHANGING BATTERIES AND ADDITIONAL NOTES To change batteries slide cover...

Страница 18: ...emote controller is lost or damaged the Liv system can be turned off directly from the in door unit Lift the front panel of the indoor wall unit then press theAUX button to turn on or turn off When th...

Страница 19: ...ur unit It is recommended that air filters be cleaned every three 3 months To access and clean the filter CARE AND CLEANING Take notice of the following items before cleaning your Liv indoor wall unit...

Страница 20: ...nit is not heating or cooling adequately Water leakage from the outdoor unit CAUSE SOLUTION Cause The system has a built in three minute delay to prevent short and or rapid cycling of the compressor S...

Страница 21: ...All restrictions must be removed to allow continuous drainage by gravity If problem persists contact a qualified service professional for assistance Cause There are a number of possible reasons Soluti...

Страница 22: ...ervice the unit Some basic maintenance might be all you need The outdoor unit will greatly benefit from a good hosing off especially in treed areas where seeds and other debris can stick to coil fins...

Страница 23: ...COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defective parts or replacement parts or new units 2 Product cleaning requir...

Отзывы: