Unitary Ducted Split AC

1

Safety Considerations

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, 

fire, electrical shock, or other conditions which may cause death, personal injury, or property 
damage. Consult a qualified installer, service agency, or your distributor or branch for information or 
assistance. The qualified installer or agency must use factory--authorized kits or accessories when 
modifying this product. Refer to the individual instructions packaged with the kits or accessories 
when installing. Follow all safety codes. Wear safety glasses, protective clothing, and work 
gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these 
instructions thoroughly and follow all warnings or cautions included in literature and attached to 
the unit. Consult local building codes and National Electrical Code (NEC) for special requirements. 
Recognize safety information. This is the safety--alert symbol .When you see this symbol on the 
unit and in instructions or manuals, be alert to the potential for personal injury. Understand these 
signal words; DANGER, WARNING, and CAUTION. These words are used with the safety--alert 
symbol. DANGER identifies the most serious hazards which will result in severe personal injury 
or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is 
used to identify unsafe practices which may result in minor personal injury or product and property 
damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, 
or operation.

WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.
Before installing, modifying, or servicing system,main electrical disconnect switch must be in 

the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch with a 
suitable warning label.

This product must not be disposed together with the domestic waste. 
This product has to be disposed at an authorized place for recycling of 
electrical and electronic appliances. 

Содержание HW18024PNa-D

Страница 1: ...you for choosing Commercial Air Conditioners please read this owner s manual carefully before operation and retain it for future reference For R410A Series Unitary Ducted Split AC Commercial Air Condi...

Страница 2: ...3 Main Page 3 4 Function Setting 3 4 1 ON OFF 3 4 2 Mode 4 4 3 Fan 4 4 4 Temperature Adjustment 4 4 5 SET Parameters Functions View and Setting 5 4 6 Enter Hold 9 4 7 Lock Function 10 4 8 Error Displ...

Страница 3: ...This is the safety alert symbol When you see this symbol on the unit and in instructions or manuals be alert to the potential for personal injury Understand these signal words DANGER WARNING and CAUT...

Страница 4: ...figure above or decided by the user Step 3 Conduct the wiring and see section 2 for more details Step 4 Reinstall the front panel 2 Wiring Terminals of the Wired Controller Fig 2 Wiring Terminals Diag...

Страница 5: ...lit AC 3 3 Main Page Fig 3 Main Page Fan Cancel Mode Set ON OFF Enter Hold 4 Function Setting 4 1 ON OFF The controller can be turned on off by pressing this button with the corresponding ON OFF symbo...

Страница 6: ...select the desirable fan option by pressing the Fan button Under the FAN ON option the fan will always keep running Under the FAN AUTO option the fan will be automatically shut down or started up in...

Страница 7: ...button Fig 8 Parameters Functions View and Setting 4 5 1 DEMAND After accessing to the DEMAND page it is available to select the desired parameter by pressing the button The upper value indicates the...

Страница 8: ...et press the Enter Hold button for confirmation to make this setting come effective and back to the previous interface If the setting is canceled prior to the confirmation then the related parameter w...

Страница 9: ...ig 12 After the time period is selected press the Enter Hold button to make a confirmation and go the setting status for timing the time period with the HOUR blinking and adjust it through the button...

Страница 10: ...hrough the or button Fig 15 After that press the Enter Hold button to make a confirmation and go back to the page shown in step and then repeat the steps for setting other time periods Fig 16 After th...

Страница 11: ...anceled by pressing the Cancel button Table 4 No Function Function Code Description 01 Memory ON The function is activated OFF The function is deactivated 02 Temperature Unit C Celsius scale F Fahrenh...

Страница 12: ...emperature Protection of the Outdoor Unit 7 F2 Outdoor Unit Tube Temperature Sensor Error 8 F4 Discharge Temperature Sensor Error 9 e5 Main Board Discharge Temperature Sensor Error 10 F3 Main Board Am...

Страница 13: ...value will be HI The wired controller applied to the inverter unit can set the temperature from 10 37 at the COOL mode and 5 32 at the HEAT mode However 16 30 is the real range which can be recognized...

Страница 14: ...ubes as directly as possible by avoiding unnecessary turns and bends 4 Leave some slack between structure and unit to absorb vibration 5 When passing refrigerant tubes through the wall seal opening wi...

Страница 15: ...s contact distributor for details and PE Certification Professional Engineer if required On rooftop applications mount on level platform or frame Place unit above a load bearing wall and isolate unit...

Страница 16: ...tubing lengths up to 36 inch may be buried without further special consideration Do not bury lines longer than 36 inch CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipmen...

Страница 17: ...ce IMPORTANT Do not apply indoor coils which are not factory approved to these units CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation Serv...

Страница 18: ...cuated using the recommended deep vacuum method of 500 microns The alternate triple evacuation method may be used if the procedure outlined below is followed IMPORTANT Always break a vacuum with dry n...

Страница 19: ...then be free of any contaminants and water vapor Final Tubing Check IMPORTANT Check to be certain factory tubing on both indoor and outdoor unit has not shifted during shipment Ensure tubes are not ru...

Страница 20: ...of adequate size per NEC to handle unit starting current Locate disconnect within sight from and readily accessible from unit per Section 440 14 of NEC WARNING A separate air switch must be furnished...

Страница 21: ...VER LOAD ENVIRONMENT TEMP SENSOR DISCHARGE GAS TEMP SENSOR Fig 26 Electric Wiring of the Outdoor Unit HW18024PNa D OUTDOOR UNIT SYMBOL NAME XT1 XT2 TERMINAL BOARD AP MAIN PCB L1 L2 INDUCTOR COMP COMPR...

Страница 22: ...r at negative pressure Do not disable low pressure switch in scroll compressor applications Dome temperatures may be hot In 3 phase applications incorrect phasing will cause reverse rotation resulting...

Страница 23: ...HEAT or COOL and fan control to ON or AUTO mode as desired Operate unit for 15 minutes Check system refrigerant charge 5 3 9 Final Checks IMPORTANT Before leaving job be sure to do the following 1 Ens...

Страница 24: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com...

Отзывы: