15

Winter Start Control 

Yes

No

No

Accumulator 

No

No

No

Motor Master Control 

Yes

No

No

Support Feet 

Recommended

No

Recommended

Table 9—Refrigerant Connections and Recommended Liquid and Vapor Tube Diameters(In.)

UNIT 

SIZE 

Liquid

Vapor

Connection Diameter

Tube Diameter  Connection Diameter  Rated Tube Diameter

24

3/8

3/8

5/8

5/8

36

3/8

3/8

3/4

3/4

42

3/8

3/8

7/8

7/8

48

1/2

1/2

7/8

7/8

Outdoor Unit Connected to Factory Approved Indoor Unit 

These outdoor units are carefully evaluated and listed with specific indoor coils for proper 

system performance. 

IMPORTANT:

 Do not apply indoor coils which are not factory approved to these units

CAUTION

UNIT DAMAGE HAZARD

Failure to follow this caution may result in equipment damage or improper operation.
Service valves must be wrapped in a heat-sinking material such as a wet cloth.

CAUTION

UNIT DAMAGE HAZARD

Failure to follow this caution may result in equipment damage or improper operation.
Installation of filter drier in liquid line is required.

Install Liquid Line Filter Drier Indoor 

Refer to Fig. 23 and install filter drier as follows: 
1. Braze 5 inch liquid tube to the indoor coil. 
2. Wrap filter drier with damp cloth. 
3. Braze filter drier to 5 inch long liquid tube from step 1. 
4. Connect and braze liquid refrigerant tube to the filter drier. 

Fig.23—Liquid Line Filter Drier 

Содержание HW18024PNa-D

Страница 1: ...you for choosing Commercial Air Conditioners please read this owner s manual carefully before operation and retain it for future reference For R410A Series Unitary Ducted Split AC Commercial Air Condi...

Страница 2: ...3 Main Page 3 4 Function Setting 3 4 1 ON OFF 3 4 2 Mode 4 4 3 Fan 4 4 4 Temperature Adjustment 4 4 5 SET Parameters Functions View and Setting 5 4 6 Enter Hold 9 4 7 Lock Function 10 4 8 Error Displ...

Страница 3: ...This is the safety alert symbol When you see this symbol on the unit and in instructions or manuals be alert to the potential for personal injury Understand these signal words DANGER WARNING and CAUT...

Страница 4: ...figure above or decided by the user Step 3 Conduct the wiring and see section 2 for more details Step 4 Reinstall the front panel 2 Wiring Terminals of the Wired Controller Fig 2 Wiring Terminals Diag...

Страница 5: ...lit AC 3 3 Main Page Fig 3 Main Page Fan Cancel Mode Set ON OFF Enter Hold 4 Function Setting 4 1 ON OFF The controller can be turned on off by pressing this button with the corresponding ON OFF symbo...

Страница 6: ...select the desirable fan option by pressing the Fan button Under the FAN ON option the fan will always keep running Under the FAN AUTO option the fan will be automatically shut down or started up in...

Страница 7: ...button Fig 8 Parameters Functions View and Setting 4 5 1 DEMAND After accessing to the DEMAND page it is available to select the desired parameter by pressing the button The upper value indicates the...

Страница 8: ...et press the Enter Hold button for confirmation to make this setting come effective and back to the previous interface If the setting is canceled prior to the confirmation then the related parameter w...

Страница 9: ...ig 12 After the time period is selected press the Enter Hold button to make a confirmation and go the setting status for timing the time period with the HOUR blinking and adjust it through the button...

Страница 10: ...hrough the or button Fig 15 After that press the Enter Hold button to make a confirmation and go back to the page shown in step and then repeat the steps for setting other time periods Fig 16 After th...

Страница 11: ...anceled by pressing the Cancel button Table 4 No Function Function Code Description 01 Memory ON The function is activated OFF The function is deactivated 02 Temperature Unit C Celsius scale F Fahrenh...

Страница 12: ...emperature Protection of the Outdoor Unit 7 F2 Outdoor Unit Tube Temperature Sensor Error 8 F4 Discharge Temperature Sensor Error 9 e5 Main Board Discharge Temperature Sensor Error 10 F3 Main Board Am...

Страница 13: ...value will be HI The wired controller applied to the inverter unit can set the temperature from 10 37 at the COOL mode and 5 32 at the HEAT mode However 16 30 is the real range which can be recognized...

Страница 14: ...ubes as directly as possible by avoiding unnecessary turns and bends 4 Leave some slack between structure and unit to absorb vibration 5 When passing refrigerant tubes through the wall seal opening wi...

Страница 15: ...s contact distributor for details and PE Certification Professional Engineer if required On rooftop applications mount on level platform or frame Place unit above a load bearing wall and isolate unit...

Страница 16: ...tubing lengths up to 36 inch may be buried without further special consideration Do not bury lines longer than 36 inch CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipmen...

Страница 17: ...ce IMPORTANT Do not apply indoor coils which are not factory approved to these units CAUTION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation Serv...

Страница 18: ...cuated using the recommended deep vacuum method of 500 microns The alternate triple evacuation method may be used if the procedure outlined below is followed IMPORTANT Always break a vacuum with dry n...

Страница 19: ...then be free of any contaminants and water vapor Final Tubing Check IMPORTANT Check to be certain factory tubing on both indoor and outdoor unit has not shifted during shipment Ensure tubes are not ru...

Страница 20: ...of adequate size per NEC to handle unit starting current Locate disconnect within sight from and readily accessible from unit per Section 440 14 of NEC WARNING A separate air switch must be furnished...

Страница 21: ...VER LOAD ENVIRONMENT TEMP SENSOR DISCHARGE GAS TEMP SENSOR Fig 26 Electric Wiring of the Outdoor Unit HW18024PNa D OUTDOOR UNIT SYMBOL NAME XT1 XT2 TERMINAL BOARD AP MAIN PCB L1 L2 INDUCTOR COMP COMPR...

Страница 22: ...r at negative pressure Do not disable low pressure switch in scroll compressor applications Dome temperatures may be hot In 3 phase applications incorrect phasing will cause reverse rotation resulting...

Страница 23: ...HEAT or COOL and fan control to ON or AUTO mode as desired Operate unit for 15 minutes Check system refrigerant charge 5 3 9 Final Checks IMPORTANT Before leaving job be sure to do the following 1 Ens...

Страница 24: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com...

Отзывы: