Unitary Ducted Split AC
9
Note:
Only when four time periods have been set and the wired controller has backed to the
page for selecting the day X, can the timing parameters be memorized together. If the setting quits
or the power failure occurs, then the setting of the timing parameters on the day X comes invalid.
4.5.4 “Func.”
Fig.18
● After going into this page, the function No. blinks and then press the “▼/▲” button to switch
the function No.
● Select the desired function No. and next press the ‘Enter/Hold” button for confirmation. After
that, the value of the selected function No. blinks and adjust it by pressing the “▼/▲” button. Then
press the “Enter/Hold” button again to save the setting and back to the previous page.
● This page will be canceled by pressing the “Cancel’ button.
Table 4
No
Function
Function Code Description
01
Memory
ON: The function is activated.
OFF: The function is deactivated
02
Temperature Unit
C :Celsius scale
F: Fahrenheit scale
03
Environment Temperature
Compensation
-5
℃~
5
℃
temperature compensation in
accordance with various environment and
location.
04
Compressor Time Lag Protection
ON: the function is activated
OFF: the function is deactivated.
05
Default Reset
ON: the default is reset
OFF: the default is not reset
4.6 “Enter/Hold”
On the temperature adjustment page, it is available to active the “Hold” function by pressing
the ‘Enter/Cancel” button, that is, the current setting temperature will be kept unchanged with the
change of the setting temperature for each timing period.
This function can be deactivated by pressing the “Enter/Hold” button again.
When this function is activated, the current setting temperature will always be displayed.