58
Removal Procedure
7.
1
2
1
2
Pipe Clamp
Auxiliary Piping
Remove the electric box subassembly
Unplug indoor temp sensor
Remove connection screws between
electric box and rear case. Loosen
clasp and remove ground wire and
evaporator. Then remove electric box.
Remove evaporator
Turn over the rear case and remove
connection screws between
connecting pipe clamp and rear case.
Loosen clasps between connecting
pipe clamp and rear case. Then
remove connecting pipe clamp.
Remove connection screws between
evaporator and motor clamp. Loosen
clasps between evaporator and rear
case. Then remove evaporator.
indoor temp sensor
remove electric box cover
electric box assy
evaporator
Содержание GWH09RA-K3DNA1A
Страница 11: ...8 Constrction views 848 540 320 763 257 540 286 12K Unit Unit mm...
Страница 46: ...43 Troubleshooting...
Страница 47: ...44 Troubleshooting...