Exploded Views and Parts list

The above data are subject to be changed without notice.

GWH09RA-K3DNA1A/I

GWH12RB-K3DNA1A/I

Product code

CB144N0020

CB144N0030

1

Front Panel Assy

20012765

20012765

1

2

Filter Sub-Assy

1112220401 

1112220401 

2

3

Screw Cover

24252016

24252016

1

4

Front Case Sub-assy

20012790

20012790

1

5

Air Louver 1

1051215603

1051215603

1

6

Air Louver 2

1051215503 

1051215503 

1

7

Helicoid Tongue

2611216302

2611216302

1

8

Left Axile Bush

10512037

10512037

1

9

Rear Case assy

22202467

22202467

1

10

Rubber Plug (Water Tray)

76712012

76712012

1

11

Ring of Bearing

26152022

26152022

1

12

O-Gasket sub-assy of Bearing

76512051

76512051

1

13

Cross Flow Fan

10352017

10352017

1

14

Evaporator Support

24212091

24212091

1

15

Evaporator Assy

01002610 

01002610 

1

16

Wall Mounting Frame

01252021

01252021

1

17

Motor Press Plate

26112161

26112161

1

18

Fan Motor

150120874

150120874

1

19

Pipe Clamp

2611216401 

2611216401 

1

20

Drainage hose

0523001401

0523001401

1

21

Step Motor

1521210801

1521210801

1

22

Crank

10582070

10582070

1

23

Guide Louver

10512203

10512203

1

24

Axile Bush

10542008

10542008

1

25

Electric Box

20112082 

20112082 

1

26

Terminal Board

42011233 

42011233 

1

27

Electric Box Cover2

20122075

20122075

1

28

Display Board

30565110

30565110

1

29

Capacitor CBB61

33010002

33010002

1

30

Jumper

4202300102

4202300104

1

31

Main Board

30138745 

30138745 

1

32

Shield cover of Electric Box sub-assy

01592073 

01592073 

1

33

Electric Box Cover1

20122103 

20122103 

1

34

Electric Box Assy

2020264401

20202644

1

35

Power Cord

400204649

400204649

1

36

Connecting Cable

400205236

400205236

1

37

Ambient Temperature Sensor

390000451

390000451

1

38

Remote Controller

30510125

30510125

1

39

Tube Sensor

390000591

390000591

1

Description

NO.

Qty

Part Code

Содержание GWH09RA-K3DNA1A

Страница 1: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Service Manual MODEL GWH09RA K3DNA1A GWH12RB K3DNA1A Refrigerant R410A...

Страница 2: ...t 7 Part 4 Refrigerant System Diagram 9 5 1 Electrical Data 10 5 2 Electrical Wiring 10 5 3 Printed Circuit Board 12 Part 5 Schematic Diagram 10 6 1 Remote Control Operations 15 6 2 Changing Batteries...

Страница 3: ...9 Troubleshooting 38 9 1 Malfunction Analysis 38 9 2 42 9 3 How to Simply Check the Main Part 45 8 1 Indoor unit 32 8 2 Outdoor unit 34 Part10 Removal Procedure 55 10 1 Removal Procedure of Indoor Uni...

Страница 4: ...1 Summary and features Indoor Unit Outdoor Unit Remote control Summary and features GWH09RA K3DNA1A I GWH12RB K3DNA1A I GWH12RB K3DNA1A O GWH09RA K3DNA1A O...

Страница 5: ...fire electric shock explosion or injury Make sure the ceiling wall is strong enough to bear the weight of the unit Make sure the noise of the outdoor unit does not disturb neighbors Properly insulate...

Страница 6: ...Fan Motor RLA A 0 10 0 10 Fan Motor Capacitor F 1 0 1 0 Input of Heater W Evaporator Form Aluminum Fin copper Tube Aluminum Fin copper Tube Pipe Diameter mm 7 7 Row fin Gap mm 2 1 4 2 1 4 Coil Length...

Страница 7: ...80 Fan Motor Speed rpm 830 660 900 Output of Fan Motor W 30 30 Fan Motor RLA A 0 30 0 15 Fan Motor Capacitor F Air Flow Volume of Outdoor Unit m3 h 1600 1800 Fan Type Axial flow Axial flow Fan Diamete...

Страница 8: ...urbo Pipe length 5m Voltage 230V Compressor Speed rps Cooling Heating Current A Current A 2 3 Capacity Variation Ratio According to Temperature 50 60 70 80 90 100 110 32 33 34 35 36 37 38 39 40 41 42...

Страница 9: ...essure Indoor Outdoor P MPa T1 C T2 C 09K Turbo 830 62 12K Turbo 900 66 in 1 3 out 2 5 7 6 20 2 5 3 0 in 75 85 out 37 43 Outdoor fan mode Compressor revolution rps Temperature condition C Model name H...

Страница 10: ...7 Constrction views 3 Construction Views 3 1 Indoor Unit Unit mm 845 130 542 173 180 275 3 2 Outdoor Unit 257 320 776 540 712 510 286 09K Unit...

Страница 11: ...8 Constrction views 848 540 320 763 257 540 286 12K Unit Unit mm...

Страница 12: ...stem Diagram Refrigerant pipe diameter Liquid 1 4 6 mm Gas 3 8 9 52mm T I N U R O O D T U O T I N U R O O D N I HEAT EXCHANGER EVAPORATOR COOLING HEATING HEAT EXCHANGER EVAPORATOR Strainer Strainer Ca...

Страница 13: ...1 DISP 2 CN2 CN1 AP1 DISPLAY 13 GENERATOR COOLPLASMA M PE XT1 W1BU W3BN N 1 OUTDOOR UNIT 2 3 COM OUT W4YEGN N W2BK BU YEGN BN L N POWER RD BU YEGN HEALTH N HEALTH L PE EVAPORATOR Symbol Color symbol...

Страница 14: ...OX MID ISOLATION SHEET L2 L2 RDRD HEATER COMP HEAT N1 BN W21 BU W10 HEAT L HEAT N2 CHASSIS HEATER LX1 1 LX1 2 AC L2 AC L3 AC N1 AC N2 CN1 OFAN OVC COMP CN3 CN2 4V E AC N AC L U V W M EH1 EH2 09K Unit...

Страница 15: ...l wire Port of indoor fan Solid state relay Auto button Feedback of indoor fan Port of motor for vertical swing Port of motor for horizontal swing Buzzer Port of indoor ambient temp sensor Port of ind...

Страница 16: ...am TOP VIEW BOTTOM VIEW 2 Outndoor unit 09K Unit Power of switch Neutral wire Live wire 4 way valve Port of fan Communication port Electronic expansion valve Overload Temp sensor Port of compressor Te...

Страница 17: ...M VIEW 12K Unit Port 1 of reactor Port 2 of reactor Outdoor fan Electronic expansion valve 4 way valve Ground wire Neutral wire Live wire Communication port to indoor unit Temp sensor Overload protect...

Страница 18: ...1 MODE icon 17 If MODE button is pressed current operation mode icon AUTO COOL DRY FAN or HEAT only for heat pump models will show ON OFF Button Set point Temperature DOWN Button Set point Temperature...

Страница 19: ...me DIGITAL display 24 This area will show the set tempe rature In SAVE mode SE will be displayed is displayed when pressing the AIR button Press this button again to clear the display AIR icon 25 29 3...

Страница 20: ...m perature Press this button again to cancel IFEEL function IFEEL SWING 7 ON OFF MODE This button is used for setting Fan Speed in the sequence that goes from AUTO to then back to Auto FAN 1 4 3 2 5 P...

Страница 21: ...press or button to adjust the time value Every press of either button changes the time setting by 1 minute Holding down either button rapidly changes the time setting by 1 minute and then 10 minutes W...

Страница 22: ...ing range It should be kept 1m away from the TV set or stereo sound sets If the remote controller does not operate normally please take the batteries out and reinsert them after 30 seconds If it still...

Страница 23: ...f Tamb Tpreset COOL mode will act the compressor and outdoor fan will run and the indoor fan will run at the set speed If Tamb Tpreset 2 the compressor will stop the outdoor fan will delay 30 seconds...

Страница 24: ...The condition and process of heating If Tamb Tpreset 2 HEAT mode will act the compressor outdoor fan and reversal valve will run the indoor fan will delay 3min to stop at the latest If Tpreset 2 Tamb...

Страница 25: ...six times in succession the compressor will not be started again Overload protection If temperature sensed by the overload sensor is over 115 the compressor will stop and the outdoor fan will stop wit...

Страница 26: ...erature and wind speed c The setting temperature keeps the same under the FAN mode and AUTO mode 6 Indoor Fan Control The Indoor Fan can be set as HIGH MED LOW by remote control and the Indoor Fan wil...

Страница 27: ...le protection PH High voltage protection PL Low voltage protection P1 Nominal cooling and heating P2 Maximum cooling and heating P3 Medium cooling and heating P0 Minimum cooling and heating 12 Drying...

Страница 28: ...should accord with installation dimension diagram requirements 9 Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swimming pool 7 1 3 Outdoor Unit Installation Posit...

Страница 29: ...ld be connected in fixed wiring Note Make sure that the Live wire or Zero line as well as the earth wire in the family power socket can not be wrong connected there should be reliable and no short cir...

Страница 30: ...utlet side Space to the floor Above Above Above Above Above Space to the obstruction Air outlet side Space to the wall Air inlet side Above Above Above The dimensions of the space necessary for proper...

Страница 31: ...ng tube The drain hose should be placed at a downward slant for easy discharge of condensate Note the insulating tube should be connected reliably with the sleve outside the outlet pipe The drain hose...

Страница 32: ...nstalling Connection Pipe 1 Align the center of the piping flare with the relevant valve 2 Screw in the flare nut by hand and then tighten thenut with spanner and torque wrench referring to the follow...

Страница 33: ...aste water formed in the outdoor unit can be drained out satisfactorily Fig 6 Manifold Valve Multimeter 76cmHg Lo Handle Charging hose Manometer Hi handle Vacuum pump Low pressure valve Base plate Out...

Страница 34: ...el from the two ends of it as the arrow direction shown Thenpull the air filter out as shown Fig a 2 Attach the healthy filter onto the air filter as shown Fig b 3 Mount the air filter properly along...

Страница 35: ...32 Exploded Views and Parts list 8 Exploded Views and Parts List 8 1 Indoor Unit 38 36 35 37 39 15 12 11 14 9 8 6 4 2 28 32 33 25 24 23 17 26 7 31 27 3 1 10 16 18 19 20 22 21 34 5 13 30 29...

Страница 36: ...l Mounting Frame 01252021 01252021 1 17 Motor Press Plate 26112161 26112161 1 18 Fan Motor 150120874 150120874 1 19 Pipe Clamp 2611216401 2611216401 1 20 Drainage hose 0523001401 0523001401 1 21 Step...

Страница 37: ...34 Exploded Views and Parts list 8 2 Outdoor Unit 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 6 09K Uuit...

Страница 38: ...nsion Valve Sub Assy 07133564 1 9 Temperature Sensor 3900030802 1 10 Clapboard Sub Assy 01233385 1 11 Magnet Coil 4300040050 1 12 4 way Valve Assy 03123385 1 13 Compressor and fittings 00103224_G 1 14...

Страница 39: ...36 Exploded Views and Parts list 12K Unit 1 3 24 9 8 10 23 21 19 22 4 6 7 11 12 15 16 18 2 17 14 20 13 28 27 26 25 29 5...

Страница 40: ...100004 1 11 Big Handle 26233433 1 12 Right Side Plate Assy 0130200404 1 13 Magnet Coil 4300040047 1 14 Temperature Sensor 39000310 1 15 Capillary Sub assy 03063401 1 16 Rear Grill 01473014 1 17 Conden...

Страница 41: ...nnection Check if the plug is properly plugged in and make the loose contact firm Fuse of controller burnt out The air condi tioner does not react after it is powered after the plug is inserted the bu...

Страница 42: ...on for the thick and thin pipes is good Heat insulation must also be provided for the joint andthe exposed part of the copper pipe Block of outdoor heat ex changer Clean the dust accumulated on the su...

Страница 43: ...stat is recommended Wrong wire connection Connect the circuit diagram correctly The built in heat protector of the motor breaks frequently because the motor is abnormal Replace the fan motor Adjust th...

Страница 44: ...or Drainage pipe blocked or broken Change drainage pipe Re wrap and make it tight Wrap of refrigerant pipe joint is not close enough Water leakage Change controller Wire loose or wrong connection In c...

Страница 45: ...12 times PL 12 High voltage protection Blink for 13 times PH 13 PFC overcurrent protection Blink for 14 times HC 14 Models of IDU and ODU don t not match Blink for 16 times LP 15 Limit frequency curr...

Страница 46: ...43 Troubleshooting...

Страница 47: ...44 Troubleshooting...

Страница 48: ...n the power and repair the power supply to restore the range 210VAC 250VAC power on and restar t the unit If the fault is eliminated Shut down the power and wait 20 minutes or use DC voltmeter to meas...

Страница 49: ...that the system pressure is too high 5 Other conditions resulting in that the system pressure becomes too high The connection of capacitor C2 is loose Stop the unit and disconnect the power supply Th...

Страница 50: ...or unit abnormal Normal protection please operate it after the outdoor ambient temperature is normalized Improve the heat dissipation environment of the unit Does the outdoor fan work normally 1 Check...

Страница 51: ...longer than 3 minutes Restart it up after 3 minutes Does startup fail Are the wires for the compressor connected correctly Is connection sequence right Connect the wires as per the connection diagram...

Страница 52: ...on Connect the wires correctly Replace the control panel AP1 If the fault is eliminated Replace the compressor End Out of step occurs in operation Is the outdoor fan working normally Is the outdoor un...

Страница 53: ...ted correctly Connect the wires correctly Resistances between the first four pins close to the terminal hole and the fifth pin are almost the same less than 100 ohm Replace the PMV If the fault is eli...

Страница 54: ...e resistance around zero The capacitor is short circuited and the capacitor should be replaced Restart the unit If the fault is eliminated Disconnect the terminals for the reactor and measure the resi...

Страница 55: ...uit of the outdoor unit If the fault is eliminated The communication circuit is abnormal Replace the main board of the indoor unit End If the fault is eliminated Replace the main board AP1 of the outd...

Страница 56: ...7 2 064 116 0 642 0 49 02 39 8 297 78 1 997 117 0 625 1 46 6 40 7 967 79 1 933 118 0 608 2 44 31 41 7 653 80 1 871 119 0 592 3 42 14 42 7 352 81 1 811 120 0 577 4 40 09 43 7 065 82 1 754 121 0 561 5 3...

Страница 57: ...9 11 06 78 2 663 117 0 833 1 62 13 40 10 62 79 2 577 118 0 811 2 59 08 41 10 2 80 2 495 119 0 77 3 56 19 42 9 803 81 2 415 120 0 769 4 53 46 43 9 42 82 2 339 121 0 746 5 50 87 44 9 054 83 2 265 122 0...

Страница 58: ...urning off all power supplies before disassembling work 2 1 2 3 Before disassembly Open the front panel Push the filter inward and then pull it outward to remove it Remove filter and horizontal louver...

Страница 59: ...e connection screw fixing indicator and then remove the indicator Remove rotating shaft of front panel from groove Then remove the front panel Remove electric box cover 2 Remove connection screws betw...

Страница 60: ...necting the vertical louver and bottom case subassembly Remove the vertical louver Remove connection screw between front case and the top of rear case Open screw cap and remove 3 connection screws Loo...

Страница 61: ...en remove electric box Remove evaporator Turn over the rear case and remove connection screws between connecting pipe clamp and rear case Loosen clasps between connecting pipe clamp and rear case Then...

Страница 62: ...emove cross flow fan blade and motor Remove screws of step motor and then remove step motor Remove 4 connection screws between motor clamp and rear case Then remove motor clamp Remove ring of bearing...

Страница 63: ...ower supplies before disassembling work 1 2 Handle 2 Top panel 1 09K Outdoor Unit Remove big handle Before disassembly Remove 1 connection screw fixing big handle and then remove the big handle Remove...

Страница 64: ...5 connection screws among front panel chassis and motor support Then remove front panel Remove axial flow fan blade Remove nut of fan blade and then remove axial flow fan blade Remove right side plat...

Страница 65: ...spots connecting the 4 way Valve Assy to take it out Note Refrigerant should be discharged firstly Welding process should be as quickly as possible and keep wrapping cotton wet all the time Be sure n...

Страница 66: ...tapping screws fixing the motor support Lift motor support to re move it 9 Disassemble motor and motor support Motor Motor support 10 Disassemble Clapboard Sub Assy Loosen the screws of the Clapboard...

Страница 67: ...r return pipe and remove the gas valve Note it is necessary to warp the gas valve when unsoldering the welding spot Remove the 2 screws fixing liquid valve Unsolder the weld ing spot connecting liquid...

Страница 68: ...r supplies before disassembling work 1 2 Handle 2 Top panel 1 Remove big handle Before disassembly Remove 1 connection screw fixing big handle and then remove the big handle Remove top cover plate Rem...

Страница 69: ...nt grill and front panel Then remove front panel Remove 5 connection screws among front panel chassis and motor support Then remove front panel Remove right side plate Remove 7 connection screws among...

Страница 70: ...e wire and disconnect the terminal Lift to re move the electric box assy 1 6 Remove electric box assy Remove the screws of theReactor sub assy and then remove it Electric box assy 2 Reactor sub assy R...

Страница 71: ...take it out Note Refrigerant should be discharged firstly Welding process should be as quickly as possible and keep wrapping cotton wet all the time Be sure not to burn out the lead out wire of compre...

Страница 72: ...the welding spot Remove the 2 screws fixing liquid valve Unsolder the weld ing spot connecting liquid valve and remove the liquid valve 2 Remove the 3 footing screws of the compressor and remove the...

Страница 73: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI Add Jinji west Rd Qianshan Zhuhai Guangdong China Post code 519070 Tel 86 756 8522219 After sale Service Dept...

Отзывы: