+PUVCNNCVKQP/CPWCN
5.Place the section with sleeve of the power connection wire into the wire groove, then cover the electric box cover, tighte n
the fixing screw,and tighten the connection wire .
Note:
When the connection wire length isn’t enough, please contact with the appointed service shop for buying a dedicated
electric wire with enough length, the connection isn’t allowed between the wire.
The wrong wiring connection isn’t allowed, it may cause the malfunction of the components.
Installation of baffle
Fig.7
Please install it after installtion of connection pipe and drainage pipe according to Fig.7.
1.Loosen the screws and adjust the baffle position up and down to clamp connection pipe/drainage pipeas much as possible.
2.Tighten the screws.
6. Recover the electric box cover.
Baffle
Hole
Screws
7.For the cooling and heating unit, the signal control wire is connected via connector and indoor unit, and clasp the signal control
wire with the wire clamp, which is under the bottom of body case.
Tighten the terminal screw.
After tightened the screw, and slightly pull the electric wire to confirm whether it is firmed or not .
Wrong earth wire connection may cause electric shock.
The electric wire covering plate must be fixed well, and tighten the connection wire, if the wire cover-ing plate isn’t installed
well, that may lead the dust, moisture enter in or due to the outside force impact, it may cause fire or electric shock.