background image

69

Maintenance

Service Manual

Above data is subject to change without notice.

NO.

Description

Part Code

Qty

GPC09AH-K3NNC5A

GPC09AH-K3NNC5D

Product  Code

CK01001484

CK010023800

1

Front Panel Assy

20006109

00000300129

1

2

Front Panel(up)

20006105

20006105

1

3

Membrane

63066048

6306603201

1

4

Display Board

30567017

30567032

1

5

Guide blade 1

10516064

10516064

5

6

Guide blade 2

10516063

10516063

1

7

Guide blade lever

10586017

10586015

1

8

Decorative Board

20196026S

20196026

1

9

Front Panel(down)

20006106

20006106

1

10

Right side plate

20056112

20056112

1

11

Discharge Tube

03636571

03636571

1

12

Inhalation Tube

03636142

03001000227 

1

13

Compressor and fittings

00101241

00106544

1

14

Overload Protector

00180240

00186504 

1

15

Motor sub-assy(flutter)

26156045

15006032

1

16

Splash Water Flywheel

10336003

10336003

1

17

Fan Motor

15016212

1501606202

1

18

Castor

24236009

24236009

4

19

Chassis

22226062

22226062

1

20

Water level switch sub-assy

26156045

26156045

1

21

water level switch base

26156041

26156041

1

22

Water Level Switch

45010211

45010211 

1

23

Water retaining box

20186259

20186259

1

24

Capillary Sub-Assy

03006121

03000600307

1

25

Condenser Assy

01106100

01100200171

1

26

Left side plate

20056111

20056111

1

27

Filter sub-assy2

11126071

11126071

1

28

Filter sub-assy1

11126070

11126070

1

29

Remote control box

20186094

20186094

1

30

Rear Plate

20056113

20056113

1

31

Evaporator Assy

01006068

01006107

1

32

Electric Box Assy

01406217

10000201588

1

33

Ambient Temperature Sensor

390000451

390000451

1

34

Main Board

3013701001

30137051

1

35

Capacitor CBB65

33000017

3300008101

1

36

Capacitor CBB61

33010010

3301074705

1

37

Electric Box Cover

01416013

01416013

1

38

Water Tray

12416009

12416009

1

39

Cover of Propeller Housing

22246086

22246086

1

40

Propeller Housing (upper)

22206044

22206044

1

41

Centrifugal fan

10316060

10316060

1

42

Propeller Housing(lower)

22206045

22206045

1

43

Guide blade lever

10586015

10586015

1

44

Air Louver 2

10516061

10516061

1

45

Air Louver 1

10516060

10516060

4

46

Fan Motor

15016069

1501606903

1

47

Motor Holder

26156089

26156089

1

48

Rear Grill

01476020

01476020

1

49

Centrifugal fan

1031606101

10316060

1

50

Diversion Circle

10376038

10376038

1

51

Power Cord

400220114

400220114

1

52

Remote Controller

30510065

30510065

1

53

Rear Clip

261160185

2611601001

1

54

Plastic Pipe End

06646017

06646017

1

55

PP hose

0523602203

0523602203

1

56

Joint

26116087

26116087

1

57

Drainage hose

05230013

05230013

1

Содержание GPC07AH-K3NNC3D

Страница 1: ...H K3NNC3D GPC08AH K3NNC3D GPC09AH K3NNC3D GPC08AH K3NNC4A GPC08AH K3NNC4B GPC07AH K3NNC4B GPC07AH K3NNC4D GPC08AH K3NNC4D GPC08AH K3NNC5A GPC09AH K3NNC5A GPC07AH K3NNC5B GPC08AH K3NNC5B GPC08AH K3NNC5...

Страница 2: ...s Maintenance 37 8 Install 40 8 1 Install Drainage Pipe 40 8 2 Install Window Frame 40 8 3 Installation and Disassembly of Heat Discharge Pipe 41 8 4 Operation test 43 8 5 Drainage way 43 8 6 Clean an...

Страница 3: ...GPC08AH K3NNC3D GPC09AH K3NNC3D GPC08AH K3NNC5A GPC09AH K3NNC5A GPC07AH K3NNC5B GPC08AH K3NNC5B GPC08AH K3NNC5C GPC09AH K3NNC5C GPC07AH K3NNC5D GPC08AH K3NNC5D GPC09AH K3NNC5D YX1F 1 Summary Part Tec...

Страница 4: ...w h SEER HSPF Application Area m2 10 16 12 16 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 3 8 Permissible Exc...

Страница 5: ...ype Centrifugal Centrifugal Diameter Length DXL mm 146X108 5 146X108 5 Fan Motor Speed H M L r min 1250 1150 1050 1250 1150 1050 Output of Fan Motor W 45 45 Fan Motor RLA A 0 41 0 41 Fan Motor Capacit...

Страница 6: ...F Application Area m2 12 18 12 18 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 3 8 Permissible Excessive Opera...

Страница 7: ...ugal Diameter Length DXL mm 146X108 5 146X108 5 Fan Motor Speed H M L r min 1250 1150 1050 1250 1150 1050 Output of Fan Motor W 45 45 Fan Motor RLA A 0 41 0 41 Fan Motor Capacitor F 3 5 3 5 Form Alumi...

Страница 8: ...ER HSPF Application Area m2 10 16 10 16 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 3 8 Permissible Excessive...

Страница 9: ...Centrifugal Diameter Length DXL mm 146X108 5 146X108 5 Fan Motor Speed H M L r min 1250 1150 1050 1250 1150 1050 Output of Fan Motor W 45 45 Fan Motor RLA A 0 41 0 41 Fan Motor Capacitor F 3 5 3 5 For...

Страница 10: ...EER HSPF Application Area m2 10 16 10 16 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 3 8 Permissible Excessiv...

Страница 11: ...entrifugal Diameter Length DXL mm 146X108 5 146X108 5 Fan Motor Speed H M L r min 1250 1150 1050 1250 1150 1050 Output of Fan Motor W 45 45 Fan Motor RLA A 0 41 0 41 Fan Motor Capacitor F 3 5 3 5 Form...

Страница 12: ...Application Area m2 10 16 10 16 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 3 8 Permissible Excessive Operat...

Страница 13: ...ntrifugal Diameter Length DXL mm 146X108 5 146X108 5 Fan Motor Speed H M L r min 1250 1150 1050 1250 1150 1050 Output of Fan Motor W 45 45 Fan Motor RLA A 0 41 0 41 Fan Motor Capacitor F 3 5 3 5 Form...

Страница 14: ...Application Area m2 10 16 10 16 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 3 8 Permissible Excessive Operati...

Страница 15: ...Diameter Length DXL mm 146X108 5 146X108 5 Fan Motor Speed H M L r min 1250 1150 1050 1250 1150 1050 Output of Fan Motor W 45 45 Fan Motor RLA A 0 41 0 41 Fan Motor Capacitor F 3 5 3 5 Form Aluminum F...

Страница 16: ...Application Area m2 10 16 10 16 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 3 8 Permissible Excessive Operati...

Страница 17: ...Diameter Length DXL mm 146X108 5 146X108 5 Fan Motor Speed H M L r min 1250 1150 1050 1250 1150 1050 Output of Fan Motor W 45 45 Fan Motor RLA A 0 41 0 41 Fan Motor Capacitor F 3 5 3 5 Form Aluminum F...

Страница 18: ...Btu w h SEER HSPF Application Area m2 10 16 10 16 Climate Type T1 T1 Isolation I I Moisture Protection IPX0 IPX0 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 3 8 Permissible...

Страница 19: ...Diameter Length DXL mm 146X108 5 146X108 5 Fan Motor Speed H M L r min 1250 1150 1050 1250 1150 1050 Output of Fan Motor W 45 45 Fan Motor RLA A 0 41 0 41 Fan Motor Capacitor F 3 5 3 5 Form Aluminum F...

Страница 20: ...Btu w h SEER HSPF Application Area m2 12 18 Climate Type T1 Isolation I Moisture Protection IPX0 Permissible Excessive Operating Pressure for the Discharge Side MPa 3 8 Permissible Excessive Operatin...

Страница 21: ...8 Evaporator Fan Type Centrifugal Diameter Length DXL mm 146X108 5 Fan Motor Speed H M L r min 1250 1150 1050 Output of Fan Motor W 45 Fan Motor RLA A 0 41 Fan Motor Capacitor F 3 5 Form Aluminum Fin...

Страница 22: ...20 Technical Information Service Manual GPC07AH K3NNC3D GPC08AH K3NNC3D GPC09AH K3NNC3D Unit mm 3 Outline Dimension Diagram 345 300 790...

Страница 23: ...21 Technical Information Service Manual GPC08AH K3NNC4A GPC07AH K3NNC4B GPC08AH K3NNC4B GPC07AH K3NNC4D GPC08AH K3NNC4D 300 355 800 Unit mm...

Страница 24: ...nformation Service Manual GPC07AH K3NNC5A GPC09AH K3NNC5A GPC07AH K3NNC5B GPC08AH K3NNC5B GPC08AH K3NNC5C GPC09AH K3NNC5C GPC07AH K3NNC5D GPC08AH K3NNC5D GPC09AH K3NNC5D MODE ON OFF MODE ON OFF 375 80...

Страница 25: ...echnical Information Service Manual 4 Refrigerant System Diagram HEAT EXCHANGE EVAPORATOR HEAT EXCHANGE CONDENSER COMPRESSOR CENTRIFUGAL FAN CENTRIFUGAL FAN Accumlator Suction Discharge Capillary Stra...

Страница 26: ...iring Diagram Instruction Electric Diagram GPC08AH K3NNC4A GPC08AH K3NNC5A GPC08AH K3NNC5C WATER MOTOR TUBE TUBE TEMP RT2 SENSOR PE ELECTRIC BOX PE 1 3 SAT PE SENSOR N3 C2 RD UP FAN MOTOR BN M1 YEGN M...

Страница 27: ...4 FAN RD W2 DISP2 WATER1 N1 AP1 R M COMP 4 L 3 K201 C1 YE W3 1 2 C YEGN COMP S W5 N3 BU BU WH YEGN GN N BN BK L POWER ROOM WATER MOTOR TUBE TUBE TEMP RT2 SENSOR WATER LEVEL SWITCH TUBE TUBE TEMP RT2 S...

Страница 28: ...GPC07AH K3NNC3D GPC07AH K3NNC4D GPC07AH K3NNC5D GPC08AH K3NNC3D GPC08AH K3NNC4D GPC08AH K3NNC5D GPC09AH K3NNC3D GPC09AH K3NNC5D 78 78 7 03 57 6 1625 7 5 9 6 7 6 1625 57 28778 7 03 28778 1 3 3 75 2 3 3...

Страница 29: ...3NNC5B GPC08AH K3NNC5B GPC08AH K3NNC5C GPC09AH K3NNC5C 1 Silk screen on main board NO NAME 1 Indoor fan 2 Fuse 3 Copper fin N3 of neutral wire 4 Piezoresistor 5 Copper fin N1 of neutral wire 6 Rectifi...

Страница 30: ...onnect neutral wire 2 Piezoresistance 3 Fuse 4 Drive replay of compressor 5 Buzzer 6 Interface of display board 7 Interface of high level detection switch 8 Terminal of outdoor tube temperature sensor...

Страница 31: ...al TOP VIEW BOTTOM VIEW 2 Silk screen on display board receiving head connect with main baord GPC08AH K3NNC4A GPC08AH K3NNC4B GPC07AH K3NNC4B GPC08AH K3NNC5A GPC09AH K3NNC5A GPC07AH K3NNC5B GPC08AH K3...

Страница 32: ...hnical Information Service Manual TOP VIEW BOTTOM VIEW receiving head connect with main baord GPC07AH K3NNC3D GPC07AH K3NNC4D GPC07AH K3NNC5D GPC08AH K3NNC3D GPC08AH K3NNC4D GPC08AH K3NNC5D GPC09AH K3...

Страница 33: ...r operates under cooling mode Press Fan Speed button to adjust fan speed Cooling indicator is ON Corresponding speed indicator is ON and dual 8 nixie tube displays set temperature Temperature setting...

Страница 34: ...en power is connected stand by condition you can operate the air conditioner through the remote controller When unit is on each time you press the button on remote controller the sending signal icon o...

Страница 35: ...ode press this button to turn on Sleep function Press this button to cancel Sleep function Under Fan and Auto mode this function is unavailable 7 TIMER Button When unit is on press this button to set...

Страница 36: ...t The distance between signal sender and receiving window should be within 8m There should be no obstacle between them Signal may be interfered easily in the room where there is fluorescent lamp or wi...

Страница 37: ...C 77o F standard heating Tpreset 20o C 68o F It will goes to auto cooling mode when Tamb 26o C 79o F and goes to auto fan mode when Tamb 20o C 68o F 20o C 68o F Tamb 23o C 73o F if the previous runnin...

Страница 38: ...not valid under auto dry and fan mode 3 8 Light Control If set the light is on with remote control the indicator lamp and dual 8 display the current setting status if set the light is off with remote...

Страница 39: ...ctric work must be performed by a licensed technician according to local regulations and the instructions given in this manual Be caution during installation and maintenance Prohibit incorrect operati...

Страница 40: ...suring tape 4 Electroprobe 7 Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Scissors saw 6 Torque wrench open end...

Страница 41: ...d installation steps in this section Preparation before installation Start installation Prepare tools Read the requirements for electric connection Check after installation and test operation Finish i...

Страница 42: ...window frame and then cut the window frame to make its width the same as the width of window A Installation in a double hung sash window 1 Cut the sponge B to a proper length and attach it to the wind...

Страница 43: ...window frame on the windowsill with screws and clips of rear connection plate required quantity is shown in the sheet below Window height H Screw quantity Clip quantity H 28 3 11 718mm 2 2 28 3 11 718...

Страница 44: ...ould be as short as possible and flat without curve to ensure smooth heat discharge As shown in following fig The length of the exhaust pipe is less than 1m It is recommended to use it with shortest l...

Страница 45: ...ondensation water will be evaporated and drained to outdoor So usually only a little condensation water will be accumulated inside the chassis and you do not need to discharge the water frequently Whe...

Страница 46: ...uld be cleaned about once every three months If there s much dust in the operation environment you can increase clean frequency Do not dry the filter with fire or hair drier Otherwise it may be deform...

Страница 47: ...able for temperature sensor 4 Main board is damaged 3 Outdoor condenser temperature sensor is open short circuited F4 OFF 3S and blinks 4 times Compressor and draw water motor stop operation Fan opera...

Страница 48: ...r H3 Indoor fan runs according to set fan and other loads will stop 1 Heat exchangers are too dirty or the air inlet outlet is blocked 2 Fan motor is not working Abnormal fan speed fan speed is too lo...

Страница 49: ...sened or poorly contacted Insert the temperature sensor tightly Yes Is malfunction eliminated Is there short circuit due to trip over of the parts Make the parts upright Is malfunction eliminated Repl...

Страница 50: ...oor outdoor heat exchanger too dirty or are the air inlet and outlet blocked Normal fluctuation is within 10 of the rated voltage on the nameplate Malfunction is eliminated No No No No No No No No No...

Страница 51: ...wires for water level switch are connected tightly Adjust connection Whether malfunction is eliminated Whether malfunction is eliminated Replace water level switch Replace the main board with the sam...

Страница 52: ...ystem System is blocked inside dirt block ice block oil block Y valve no fully open Compressor doesn t work normally Strange noise or leakage occurs Make compressor run normally Casing is too hot Repl...

Страница 53: ...otor is not working Abnormal fan speed fan speed is too low or the fan doesn t run End Remove blockage in the system System is blocked inside dirt block ice block oil block Y valve no fully open Compr...

Страница 54: ...k normally Strange noise or leakage occurs Make compressor run normally Casing is too hot Replace a main board with the same model Malfunction is eliminated Malfunction is eliminated Malfunction is el...

Страница 55: ...lace remote controller Water inside water chassis is full Dual8 nixie tube displays H8 and buzzer gives out 8 sounds water over flow protection Discharge condensate water Malfunction of water level sw...

Страница 56: ...with an universal meter and find that the capacity is out of the deviation range indicated on the nameplate of fan capacitor Replace the compressor capacitor Power voltage is a little low or high Use...

Страница 57: ...0 Exploded View and Parts List GPC07AH K3NNC3D GPC08AH K3NNC3D GPC09AH K3NNC3D 54 53 52 51 50 49 48 1 2 3 4 5 6 7 8 9 10 12 11 13 15 16 17 18 19 20 21 22 23 24 14 25 26 27 28 29 30 31 32 33 34 35 36 3...

Страница 58: ...side plate 20056111 20056111 1 24 Filter sub assy2 11126071 11126071 1 25 Filter sub assy1 11126070 11126070 1 26 Remote controlbox 20186094 20186094 1 27 Rear Plate 20056113 20056113 1 28 Evaporator...

Страница 59: ...Condenser Assy 01100200171 1 23 Left side plate 20056111 1 24 Filter sub assy2 11126071 1 25 Filter sub assy1 11126070 1 26 Remote controlbox 20186094 1 27 Rear Plate 20056113 1 28 Evaporator Assy 010...

Страница 60: ...08AH K3NNC4A GPC07AH K3NNC4B GPC08AH K3NNC4B GPC07AH K3NNC4D GPC08AH K3NNC4D 55 54 8 9 10 11 12 13 14 15 16 17 18 19 20 21 49 50 51 52 53 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42...

Страница 61: ...111 1 25 Filter sub assy2 11126071 11126071 1 26 Filter sub assy1 11126070 11126070 1 27 Remote control box 20186094 20186094 1 28 Rear Plate 20056113 20056113 1 29 Evaporator Assy 01006100 01006107 1...

Страница 62: ...6111 1 25 Filter sub assy2 11126071 11126071 1 26 Filter sub assy1 11126070 11126070 1 27 Remote control box 20186094 20186094 1 28 Rear Plate 20056113 20056113 1 29 Evaporator Assy 01106131 01006065...

Страница 63: ...24 Left side plate 20056111 1 25 Filter sub assy2 11126071 1 26 Filter sub assy1 11126070 1 27 Remote control box 20186094 1 28 Rear Plate 20056113 1 29 Evaporator Assy 01006107 1 30 Electric Box Assy...

Страница 64: ...20 21 22 23 24 25 51 52 53 54 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 2 3 4 5 6 7 8 9 GPC08AH K3NNC5A GPC07AH K3NNC5B GPC08AH K3NNC5B GPC08AH K3NNC5C GPC09AH K3NN...

Страница 65: ...Left side plate 20056111 2005611102 1 27 Filter sub assy2 11126071 1112607102 1 28 Filter sub assy1 11126070 11126070 1 29 Remote control box 20186094 2018609402 1 30 Rear Plate 20056113 2005611302 1...

Страница 66: ...25 1 25 Condenser Assy 01106100 01106100 1 26 Left side plate 2005611102 2005611101 1 27 Filter sub assy2 1112607102 1112607101 1 28 Filter sub assy1 11126070 11126070 1 29 Remote control box 20186094...

Страница 67: ...513 03006121 1 25 Condenser Assy 01106106 01106100 1 26 Left side plate 2005611102 2005611102 1 27 Filter sub assy2 1112607102 1112607102 1 28 Filter sub assy1 11126070 11126070 1 29 Remote control bo...

Страница 68: ...1 25 Condenser Assy 01106132 01106132 1 26 Left side plate 20056111 2005611102 1 27 Filter sub assy2 11126071 1112607102 1 28 Filter sub assy1 11126070 11126070 1 29 Remote control box 20186094 20186...

Страница 69: ...01106132 01100200145 1 26 Left side plate 20056111 2005611102 20056111 1 27 Filter sub assy2 11126071 1112607102 11126071 1 28 Filter sub assy1 11126070 11126070 11126070 1 29 Remote control box 20186...

Страница 70: ...549 03006549 1 25 Condenser Assy 01106132 01106132 1 26 Left side plate 20056111 2005611102 1 27 Filter sub assy2 11126071 1112607102 1 28 Filter sub assy1 11126070 11126070 1 29 Remote control box 20...

Страница 71: ...121 03000600307 1 25 Condenser Assy 01106100 01100200171 1 26 Left side plate 20056111 20056111 1 27 Filter sub assy2 11126071 11126071 1 28 Filter sub assy1 11126070 11126070 1 29 Remote control box...

Страница 72: ...remote controller box 2 Remove filter sub assy Break out the remote controller box then push the middle of remote controller box to make clasps remove from remote controller box Pull the filter sub a...

Страница 73: ...Remove panel assy Remove the five screws fixing panel lift and pull outward to remove the panel screws panel assy Remove the six screws fixing rear plate to remove the rear plate screws rear plate fo...

Страница 74: ...ws as diagram shown to remove left side plate Remove right side plate unscrew 7 screws of right side plate to remove it 6 Remove electric box cover Unscrew 2 screw to remove the electric box cover Ste...

Страница 75: ...rew 3 screws of electric box to remove electric box assembly 8 Remove facing bar Unscrew 2 screws fixing facing bar to remove it 9 Remove volute cover Unscrew 3 screws fixing volute cover to remove it...

Страница 76: ...ld then unscrew 5 screws fixing evaporator to remove it note The refrigerant must be discharg ed before unsoldering 11 Remove facing bar 2 Unscrew 3 screws fixing facing bar to remove the facing bar 2...

Страница 77: ...vice Manual 12 Remove facing bar 1 Unscrew 4 screws fixing facing bar to remove the facing bar 1 13 Remove duct assembly Unscrew 2 screws to remove duct assembly Step Procedure screws screws duct asse...

Страница 78: ...ove volute upper and mesh enclosure Break out connecting rod and vertical louver by hand to remove them Unscrew 4 screws as diagram shown to remove volute upper and mesh enclosure Step Procedure verti...

Страница 79: ...crew nuts of centrifugal louver upper and motor to remove centrifugal louver upper 16 Remove volute lower and water tray Unscrew 3 screws as diagram shown to remove volute lower and water tray Step Pr...

Страница 80: ...nscrew 4 screws fixing diversion ring to remove diversion ring Unscrew nuts of centrifugal louver anticlockwise take out gasket to remove the centrifugal louver lower Unscrew 3 screws fixing motor to...

Страница 81: ...r retaining tray to remove water retaining tray 22 Remove condenser assembly Unscrew 2 screws then unsolder the spot weld to remove condenser assembly Note The refrigerant must be discharged before un...

Страница 82: ...switch sub assy and caster wheel 1 Unscrew 2 screws of bottom of sub assy to remove motor sub assy 2 Unscrew 2 screws fixing water level switch to remove water level switch sub assy 3 Unscrew 8 screw...

Страница 83: ...16 84 85 84 2 29 39 40 39 2 4 63 62 6 17 86 87 86 30 41 42 41 5 64 65 64 4 18 88 89 87 8 31 43 44 42 8 6 66 67 66 2 19 90 89 6 32 45 44 6 7 68 69 68 20 91 92 91 4 33 46 47 46 4 8 70 71 69 8 21 93 94...

Страница 84: ...1 0 737 5 63 46 34 10 2 73 2 358 112 0 717 4 60 23 35 9 779 74 2 28 113 0 697 3 57 18 36 9 382 75 2 206 114 0 678 2 54 31 37 9 003 76 2 133 115 0 66 1 51 59 38 8 642 77 2 064 116 0 642 0 49 02 39 8 29...

Страница 85: ...3 144 112 0 956 4 80 31 35 13 04 74 3 04 113 0 93 3 76 24 36 12 51 75 2 94 114 0 904 2 72 41 37 12 76 2 844 115 0 88 1 68 79 38 11 52 77 2 752 116 0 856 0 65 37 39 11 06 78 2 663 117 0 833 1 62 13 40...

Страница 86: ...5 362 9 24 51 41 63 10 93 102 3 13 14 342 8 25 49 19 64 10 54 103 3 04 13 323 9 26 47 08 65 10 18 104 2 96 12 306 2 27 45 07 66 9 83 105 2 87 11 289 6 28 43 16 67 9 49 106 2 79 10 274 29 41 34 68 9 17...

Страница 87: ...65 64 48 75 44 81 41 48 38 59 36 05 33 77 31 24 28 93 26 80 24 83 63 53 64 49 31 45 65 42 48 39 68 37 17 34 34 31 74 29 36 27 15 62 59 14 54 36 50 32 46 82 43 73 40 97 37 83 34 96 32 32 29 87 61 65 31...

Страница 88: ...6 55 15 42 14 34 61 30 33 28 17 26 14 24 23 22 42 20 71 19 37 18 10 16 88 15 72 60 33 47 31 05 28 78 26 64 24 62 22 70 21 24 19 84 18 50 17 23 59 37 00 34 31 31 77 29 39 27 13 24 99 23 37 21 83 20 36...

Страница 89: ...79 80 1058 15 942 75 863 43 787 81 715 55 646 36 30 1906 00 1731 91 1568 38 1414 20 1268 36 1130 00 1034 60 943 64 856 73 773 51 29 2300 00 2089 81 1892 37 1706 22 1530 13 1363 08 1244 55 1131 54 1023...

Страница 90: ...13 68 48 63 03 57 78 52 70 49 02 45 46 42 00 38 65 44 89 00 82 54 76 32 70 33 64 54 58 96 54 75 50 69 46 74 42 92 43 101 00 93 48 86 25 79 28 72 55 66 06 61 28 56 65 52 17 47 82 42 115 00 106 23 97 79...

Страница 91: ...5 19 4 93 4 68 4 44 4 20 4 01 3 83 3 65 3 47 3 30 64 5 88 5 59 5 31 5 04 4 78 4 52 4 31 4 11 3 91 3 72 3 53 63 6 31 6 00 5 70 5 41 5 13 4 85 4 63 4 41 4 20 4 00 3 80 62 6 84 6 50 6 17 5 84 5 53 5 22 4...

Страница 92: ...95 29 315 00 291 16 267 97 245 41 223 43 202 00 187 96 174 26 160 88 147 81 135 03 28 372 00 342 25 313 32 285 16 257 73 231 00 215 94 201 25 186 90 172 88 159 17 27 441 00 404 50 369 01 334 45 300 8...

Страница 93: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn Http www gree com Add Unit 2612 26 F Miramar Tower 132 Nathan Road TST Kowloon HK...

Отзывы: