43
Maintenance
Service Manual
(2) Press the clasp and lift joint A upwards to remove it.(As shown in following fig)
●Put through the power supply and then press ON/OFF button on remote controller to start the unit.
●Press mode button to select auto, cooling, drying, fan or heating function, and then check if the unit
operates normally.
●If ambient temperature is below 16°C, the unit can't operate in cooling mode.
clasp
joint A
upwards
disassemble
● In cooling or drying operation, the condensation water will be drained to the chassis and spattered by water-striking motor. As
the temperature of condenser is high, most of the condensation water will be evaporated and drained to outdoor. So usually, only
a little condensation water will be accumulated inside the chassis and you do not need to discharge the water frequently.
● When the chassis is full with water, the buzzer will give out 8 sounds and "H8" is displayed to remind user to discharge water:
●Move the unit to a suitable place for discharging water; do not tilt the unit and keep it horizontal during moving;
●Take the drainage pipe from the clip and pull out the rubber plug on the drainage pipe to discharge water;
●Put back the rubber plug onto drainage pipe after finishing discharging water and then fix the pipe on the clip.
●After full water protection is eliminated and the compressor has been stopped for 3 minutes, the unit will resume operation.
8.4 Operation test
8.5 Drainage way