Multi Variable Air Conditioners Two-way Cassette Indoor Unit

 

1 Safety Precautions   

WARNING

 

(1) 

This product can’t be installed at corrosive, inflammable or explosive environment or the place with 
special requirements, such as kitchen. Otherwise, it will affect the normal operation or shorten the service 
life of the unit, or even cause fire hazard or serious injury. As for above special places, please adopt 
special air conditioner with anti-corrosive or anti-explosion function. 

(2) Follow this instruction to complete the installation work. Please carefully read this manual before unit 

startup and service. 

(3) Wire size of power cord should be large enough.The damaged power cord and connection wire should 

be replaced by exclusive cable.   

(4) After connecting the power cord, please fix the electric box cover properly in order to avoid accident.   

(5) Never fail to comply with the nitrigen charge requirements.Charge nitrogen when welding pipes.   

(6) Never short-circiut or cancel the pressure switch to prevent unit damage.   

(7) Please firstly connect the wired controller before energization, otherwise wired controller can not be 

used.   

(8) Before using the unit, please check if the piping and wiring are correct to avoid water leakage, refrigerant 

leakage, electric shock, or fire etc.   

(9) Do not insert fingers or objects into air outlet/inlet grille.   

(10) Open the door and window and keep good ventilation in the room to avoid oxygen deficit when the 

gas/oil supplied heating equipment is used.   

(11) Never start up or shut off the air conditioner by means of directly plug or unplug the power cord.   

(12) Turn off the unit after it runs at least five minutes; otherwise it will influence oil return of the compressor.   

(13) Do not allow children operate this unit.   

(14) Do not operate this unit with wet hands.   

(15) Turn off the unit or cut off the power supply before cleaning the unit, otherwise electric shock or injury 

may happen.   

(16) Never spray or flush water towards unit, otherwise malfunction or electric shock may happen.   

(17) Do not expose the unit to the moist or corrosive circumstances.   

(18) Under cooling mode, please don't set the room temperature too low and keep the temperature 

difference between indoor and outdoor unit within 5

(41

).   

(19) User is not allowed to repair the unit. Fault service may cause electric shock or fire accidents. Please 

contact Gree appointed service center for help.   

(20) Before installation, please check if the power supply is in accordance with the requirements specified on 

the nameplate. And also take care of the power safety.   

(21) Installation should be conducted by dealer or qualified personnel. Please do not attempt to install the 

unit by yourself. Improper handling may result in water leakage, electric shock or fire disaster etc.. 

(22) Be sure to use the exclusive accessory and part to prevent the water leakage, electric shock and fire 

accidents.   

(23) Make sure the unit can be earthed properly and soundly after plugging into the socket so as to avoid 

electric shock. Please do not connect the ground wire to gas pipe, water pipe, lightning rod or telephone 
line.   

(24) Electrify the unit 8 hours before operation. Please switch on for 8 hours before operation. Do not cut off 

the power when 24 hours short-time halting (to protect the compressor).   

(25) If refrigerant leakage happens during installation, please ventilate immediately. Poisonous gas will 

emerge if the refrigerant gas meets fire.   

(26) Volatile liquid, such as diluent or gas will damage the unit appearance.Only use soft cloth with a little 

neutral detergent to clean the outer casing of unit.   

(27) If anything abnormal happens (such as burning smell), please power off the unit and cut off the main 

power supply, and then immerdiately contact Gree appointed service center.If abnormality keeps going, 
the unit might be damaged and lead to electric shock or fire.   

Any  personal  injury  or  property  loss  caused  by  improper  installation,  improper 

debug, and unnecessary repair or not following the instructions of this manual should 

not be the responsibility of Gree Electric Appliances, Inc. of Zhuhai.  

Содержание GMV-ND09TS/A-T

Страница 1: ...anual Original Instructions Commercial Air Conditioners Multi Variable Air Conditioners Two way Cassette Indoor Unit Models GMV ND09TS A T U GMV ND12TS A T U GMV ND15TS A T U GMV ND18TS A T U GMV ND24...

Страница 2: ...ex factory date 2 Malfunction details before and after the malfunction occurs 7 Each unit has been strictly tested and proved to be qualified before ex factory In order to prevent units from being dam...

Страница 3: ...System Testing 10 4 4 Panel installation 13 4 5 Installation of Wired Controller 15 5 Wiring Work 15 5 1 Connection of Wire and Patch Board Terminal 15 5 2 Power Cord Connection 16 5 3 Connection of C...

Страница 4: ...sh water towards unit otherwise malfunction or electric shock may happen 17 Do not expose the unit to the moist or corrosive circumstances 18 Under cooling mode please don t set the room temperature t...

Страница 5: ...inage Pipe Connection Pipe Drainage Device Air Inlet Grille With Filter Main Unit Louver Panel 2 2 Rated Working Condition Indoor Side Condition Outdoor Side Condition Dry Bulb Temp C Wet Bulb Temp C...

Страница 6: ...e 5 Sponge 1 To insulate the drain pipe 6 Fastener 4 To fasten the sponge 7 paper pattern for installation 1 Locate the drill hole on ceiling 8 Tapping screw with washer 4 Fix paper pattern 9 Remote c...

Страница 7: ...d noise Even if the distance is 1m 39 3 8 in when there is strong electric wave noise may still occur Unit mm in Fig 3 2 1 1 The unit shall be installed in accordance with national standards or local...

Страница 8: ...t Ordinary polyvinyl chloride sheathed cord 60227 IEC 52 60227 IEC 53 L 250m L 820 1 5ft 2 0 75 2 1 25 2 AWG18 2 AWG16 IEC 60227 5 1 Total length of communication line can t exceed 250m 820 1 5ft 2 Th...

Страница 9: ...s necessary to use shielded wire 3 4 Wiring Requirements Power Cord Size and Air Switch Capacity Model Power Supply MCA A MOP A GMV ND09TS A T U 208 230V 1ph 60Hz 1 15 GMV ND12TS A T U 1 15 GMV ND15TS...

Страница 10: ...43 56 13 16 6 35 1 4 9 52 3 8 GMV ND12TS A T U GMV ND15TS A T U 1200 47 1 4 1252 49 5 16 1403 55 1 4 1443 56 13 16 6 35 1 4 12 7 1 2 GMV ND18TS A T U GMV ND24TS A T U 1200 47 1 4 1252 49 5 16 1403 55...

Страница 11: ...of the hanger bracket The washer fixing plate will prevent the washer from falling 3 The usage of paper pattern Refer to paper pattern of installation for ceiling opening dimension The center of ceili...

Страница 12: ...d then tighten the flaring nut with hand as shown in fig 4 2 1 2 Tighten the flaring nut with torque wrench Fig 4 2 1 3 Use pipe bend when bending the pipe and the bending angle should not be too smal...

Страница 13: ...the drainage pipelines are used for several units the position of pipeline should be about 100mm 4 in lower than the drainage port of each unit In this case thicker pipes should be applied Fig 4 3 1...

Страница 14: ...pe is vertical with the unit the raising height should be less than C Unit mm in Fig 4 3 3 Model A mm in B mm in C mm in GMV ND09TS A T U GMV ND12TS A T U GMV ND15TS A T U GMV ND18TS A T U GMV ND24TS...

Страница 15: ...e water over the electrical components e g water pump etc 2 In case of commissioning finished please energize the IDUs and switch to cooling or dry mode meanwhile the water pump operates you can check...

Страница 16: ...per decorative panel installation could cause the following problems Fig 4 4 1 2 Ensure that its clearance free between decoration panel and ceiling board after installation if not please adjust the b...

Страница 17: ...pipe Fig 4 4 4 2 Adjust the position of panel to make the panel holes fix at the holes on the unit 3 Fix the 4 screws at the two side of panel and then fix the 2 screws in the middle of panel 4 Insta...

Страница 18: ...ircuit breaker for branch circuit according to related regulations and electrical standards 6 Keep cable away from refrigerant pipings compressor and fan motor 7 The communication wires should be sepa...

Страница 19: ...ing operation all indoor units connected to the same outdoor unit system must be kept energized status Otherwise the unit can t operate normally Fig 5 2 1 For units with single phase power supply 1 De...

Страница 20: ...communication bus terminal D1 and D2 as shown in fig 5 3 2 terminal resistor is provided with each ODU 5 4 Connection of Communication Wire for Wired Controller 1 Detach the electric box cover 2 Let...

Страница 21: ...be set as master one and slave one 4 One wired controller can control 16 indoor unitS in maximum at the same time As shown in Fig 5 5 1 1 The type of indoor units must be the same if they are control...

Страница 22: ...Multi Variable Air Conditioners Two way Cassette Indoor Unit 19 Fig 5 5 1...

Страница 23: ...it If the filter is very dirty e g greasy you can clean it using warm water below 45 C that is mixed with mild detergent Then let it dry naturally in cool places 2 If the air conditioner is used in du...

Страница 24: ...Water Temperature Sensor Error L8 Power Insufficiency Protection d7 Humidity Sensor Error C0 Communication Error L9 Quantity Of Group Control Indoor Units Setting Error d8 Water Temperature Error AJ...

Страница 25: ...ked Too heavy heat load of room e g too many people Door or windows is open Inlet and outlet of IDU are blocked Setting temperature is too high or refrigerant leaks Refrigerant is insufficient e g ref...

Страница 26: ......

Отзывы: