7 Table of Error Codes for Indoor Unit 

Error 

Code 

Content 

Error 

Code 

Content 

Error 

Code 

Content 

L0 

Indoor Unit Error 

LA 

Indoor Units 

Incompatibility Error 

d9 

Jumper Cap Error 

L1 

Indoor Fan Protection 

LH 

Low Air Quality 

Warning 

dA 

Indoor Unit Network 

Address Error 

L2 

E-heater Protection 

LC 

ODU-IDU 

Incompatibility Error 

dH 

Wired Controller PCB 

Error 

L3 

Water Full Protection 

d1 

Indoor Unit PCB Error 

dC 

Capacity DIP Switch 

Setting Error. 

L4 

Wired Controller Power 

Supply Error 

d3 

Ambient Temperature 

Sensor Error 

dL 

Outlet Air Temperature 

Sensor Error 

L5 

Freeze protection 

d4 

Inlet Pipe Temperature 

Sensor Error 

dE 

Indoor Unit CO

2

 

Sensor Error 

L7 

No Master Indoor Unit 

Error 

d6 

Outlet Pipe 

Temperature Sensor 

Error 

dy 

Water Temperature 

Sensor Error 

L8 

Power Insufficiency 

Protection 

d7 

Humidity Sensor Error 

C0 

Communication Error 

L9 

Quantity Of Group 

Control Indoor Units 

Setting Error 

d8 

Water Temperature 

Error 

AJ 

Filter Cleaning 

Reminder 

db 

Special Code: Field Debugging Code 

8 Display of Light Board 

The  panel  of  this  model  is  without  nixie  tube  display.  The  error  codes  will  be 

displayed  through  the  power  light,  operation  light  and  timer  light; 

  and 

 

stand for on, off and blink respectively. 

Power light 

○ 

◎ 

◎ 

◎ 

◎ 

Operation light 

◎ 

● 

○ 

○ 

◎ 

Timer light 

● 

○ 

● 

○ 

● 

Error code display sheet 

Error code  C0 

A0 

A3   

L0 

L1 

L3 

L5 

d1 

d3 

d4 

d6 

d7 

E0 

db 

A4 

Power 

light 

◎ 

○ 

○ 

● 

● 

● 

○ 

◎ 

◎ 

◎ 

● 

○ 

● 

◎ 

Operation 

light 

◎ 

◎ 

○ 

● 

○ 

◎ 

● 

○ 

● 

◎ 

◎ 

◎ 

◎ 

● 

Timer light 

◎ 

◎ 

◎ 

◎ 

◎ 

◎ 

◎ 

◎ 

◎ 

○ 

○ 

○ 

● 

● 

Error de

scri

ption

 

Co
mmunicati

o

n e
rror

 

T

o b
e d
e

bugge

d

 

De
frostin

g

 

Ind
oo
r u
ni

error

 

Ind
oo
r f

an
 pro
tectio

n

 

W

ate
r f

ul

l pro

te

ction

 

Freeze

 pro

tecti

on
 

Ind
oo
r u
ni

PC

B error

 

Ambi

e

nt t

emp

e

ratu

re 

sen

sor e

rr

or

 

Inle

pi

p

e temp

era

ture

 

sen

sor e

rr

or

 

Outle

pi

pe
 t

em

pe
ratu

re 

sen

sor e

rr

or

 

Hu
midity 

sen

s

or e

rror

 

Outdo

or u

n

it er

ror
 

Fiel

d d

eb
u

ggin

g co

de
 

oi

l retu

rn

 

Содержание GMV-ND09TS/A-T

Страница 1: ...anual Original Instructions Commercial Air Conditioners Multi Variable Air Conditioners Two way Cassette Indoor Unit Models GMV ND09TS A T U GMV ND12TS A T U GMV ND15TS A T U GMV ND18TS A T U GMV ND24...

Страница 2: ...ex factory date 2 Malfunction details before and after the malfunction occurs 7 Each unit has been strictly tested and proved to be qualified before ex factory In order to prevent units from being dam...

Страница 3: ...System Testing 10 4 4 Panel installation 13 4 5 Installation of Wired Controller 15 5 Wiring Work 15 5 1 Connection of Wire and Patch Board Terminal 15 5 2 Power Cord Connection 16 5 3 Connection of C...

Страница 4: ...sh water towards unit otherwise malfunction or electric shock may happen 17 Do not expose the unit to the moist or corrosive circumstances 18 Under cooling mode please don t set the room temperature t...

Страница 5: ...inage Pipe Connection Pipe Drainage Device Air Inlet Grille With Filter Main Unit Louver Panel 2 2 Rated Working Condition Indoor Side Condition Outdoor Side Condition Dry Bulb Temp C Wet Bulb Temp C...

Страница 6: ...e 5 Sponge 1 To insulate the drain pipe 6 Fastener 4 To fasten the sponge 7 paper pattern for installation 1 Locate the drill hole on ceiling 8 Tapping screw with washer 4 Fix paper pattern 9 Remote c...

Страница 7: ...d noise Even if the distance is 1m 39 3 8 in when there is strong electric wave noise may still occur Unit mm in Fig 3 2 1 1 The unit shall be installed in accordance with national standards or local...

Страница 8: ...t Ordinary polyvinyl chloride sheathed cord 60227 IEC 52 60227 IEC 53 L 250m L 820 1 5ft 2 0 75 2 1 25 2 AWG18 2 AWG16 IEC 60227 5 1 Total length of communication line can t exceed 250m 820 1 5ft 2 Th...

Страница 9: ...s necessary to use shielded wire 3 4 Wiring Requirements Power Cord Size and Air Switch Capacity Model Power Supply MCA A MOP A GMV ND09TS A T U 208 230V 1ph 60Hz 1 15 GMV ND12TS A T U 1 15 GMV ND15TS...

Страница 10: ...43 56 13 16 6 35 1 4 9 52 3 8 GMV ND12TS A T U GMV ND15TS A T U 1200 47 1 4 1252 49 5 16 1403 55 1 4 1443 56 13 16 6 35 1 4 12 7 1 2 GMV ND18TS A T U GMV ND24TS A T U 1200 47 1 4 1252 49 5 16 1403 55...

Страница 11: ...of the hanger bracket The washer fixing plate will prevent the washer from falling 3 The usage of paper pattern Refer to paper pattern of installation for ceiling opening dimension The center of ceili...

Страница 12: ...d then tighten the flaring nut with hand as shown in fig 4 2 1 2 Tighten the flaring nut with torque wrench Fig 4 2 1 3 Use pipe bend when bending the pipe and the bending angle should not be too smal...

Страница 13: ...the drainage pipelines are used for several units the position of pipeline should be about 100mm 4 in lower than the drainage port of each unit In this case thicker pipes should be applied Fig 4 3 1...

Страница 14: ...pe is vertical with the unit the raising height should be less than C Unit mm in Fig 4 3 3 Model A mm in B mm in C mm in GMV ND09TS A T U GMV ND12TS A T U GMV ND15TS A T U GMV ND18TS A T U GMV ND24TS...

Страница 15: ...e water over the electrical components e g water pump etc 2 In case of commissioning finished please energize the IDUs and switch to cooling or dry mode meanwhile the water pump operates you can check...

Страница 16: ...per decorative panel installation could cause the following problems Fig 4 4 1 2 Ensure that its clearance free between decoration panel and ceiling board after installation if not please adjust the b...

Страница 17: ...pipe Fig 4 4 4 2 Adjust the position of panel to make the panel holes fix at the holes on the unit 3 Fix the 4 screws at the two side of panel and then fix the 2 screws in the middle of panel 4 Insta...

Страница 18: ...ircuit breaker for branch circuit according to related regulations and electrical standards 6 Keep cable away from refrigerant pipings compressor and fan motor 7 The communication wires should be sepa...

Страница 19: ...ing operation all indoor units connected to the same outdoor unit system must be kept energized status Otherwise the unit can t operate normally Fig 5 2 1 For units with single phase power supply 1 De...

Страница 20: ...communication bus terminal D1 and D2 as shown in fig 5 3 2 terminal resistor is provided with each ODU 5 4 Connection of Communication Wire for Wired Controller 1 Detach the electric box cover 2 Let...

Страница 21: ...be set as master one and slave one 4 One wired controller can control 16 indoor unitS in maximum at the same time As shown in Fig 5 5 1 1 The type of indoor units must be the same if they are control...

Страница 22: ...Multi Variable Air Conditioners Two way Cassette Indoor Unit 19 Fig 5 5 1...

Страница 23: ...it If the filter is very dirty e g greasy you can clean it using warm water below 45 C that is mixed with mild detergent Then let it dry naturally in cool places 2 If the air conditioner is used in du...

Страница 24: ...Water Temperature Sensor Error L8 Power Insufficiency Protection d7 Humidity Sensor Error C0 Communication Error L9 Quantity Of Group Control Indoor Units Setting Error d8 Water Temperature Error AJ...

Страница 25: ...ked Too heavy heat load of room e g too many people Door or windows is open Inlet and outlet of IDU are blocked Setting temperature is too high or refrigerant leaks Refrigerant is insufficient e g ref...