Preface 

For correct installation and operation, please read all instructions carefully. Before 

reading the instructions, please be aware of the following items:  

 

This is the safety alert symbol. It is used to alert you to potential personal injury 
hazards. Obey all safety messages that follow this symbol to avoid possible injury or 
death. 

WARNING 

This mark indicates procedures which, if improperly performed, might lead to the death 
or serious injury of the user. 

CAUTION 

This mark indicates procedures which, if improperly performed, might possibly result in 
personal harm to the user, or damage to property. 

 

NOTICE is used to address practices not related to personal injury. 

 

WARNING

 

(1) Instructions for installation and use of this product are provided by the manufacturer.   

(2) Installation must be performed in accordance with the requirements of NEC and CEC by authorized personnel 

only. 

(3) For the safe operation of this unit, please read and follow the instructions carefully. 

(4) During operation, total capacity of indoor units should not exceed the total capacity of outdoor units. Otherwise, 

poor effect of cooling or heating may result. 

(5) Direct operators or maintainers should well keep this manual. 

(6) If this unit fails to operate normally, please contact our service center as soon as possible and provide the 

following information:         

1) Content on the nameplate (model number, cooling capacity, production code, ex-factory date. 
2) Malfunction details (before and after the malfunction occurs. 

(7) Each unit has been strictly tested and proved to be qualified before ex-factory. In order to prevent units from being 

damaged or operating normally because of improper disassembly, please do not disassemble the unit by yourself. 
If you need to disassemble and check units, please contact our service center. We will send specialists to guide 
the disassembly. 

(8) Under the standby status, the unit will consume a little power for ensuring reliability of complete unit, maintaining 

normal communication and preheating refrigerant. When the unit won’t be used for a long time, cut off the power 
of the complete unit. However, please preheat it when operating the unit next time. 

(9) All graphics in this manual is only for your reference. For sales or production reasons, these graphics are subject 

to change by manufacturer without prior notice. 

(10) These instructions shall also be available in an alternative format, e.g. on a website. 

User Notice 

●  This  appliance  can  be  used  by  children  aged  from  8  years  and  above  and 

persons  with  reduced  physical,  sensory  or  mental  capabilities  or  lack  of  experience 
and  knowledge  if  they  have  been  given  supervision  or  instruction  concerning  use  of 
the  appliance  in  a  safe  way  and  understand  the  hazards  involved  .Children  shall  not 
play with the appliance .Cleaning and user maintenance shall not be made by children 
without supervision. 

● DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection 

of such waste separately for special treatment is necessary. 

 

R410A (R32/125:50/50):2087.5

 

Содержание GMV-ND09TS/A-T

Страница 1: ...anual Original Instructions Commercial Air Conditioners Multi Variable Air Conditioners Two way Cassette Indoor Unit Models GMV ND09TS A T U GMV ND12TS A T U GMV ND15TS A T U GMV ND18TS A T U GMV ND24...

Страница 2: ...ex factory date 2 Malfunction details before and after the malfunction occurs 7 Each unit has been strictly tested and proved to be qualified before ex factory In order to prevent units from being dam...

Страница 3: ...System Testing 10 4 4 Panel installation 13 4 5 Installation of Wired Controller 15 5 Wiring Work 15 5 1 Connection of Wire and Patch Board Terminal 15 5 2 Power Cord Connection 16 5 3 Connection of C...

Страница 4: ...sh water towards unit otherwise malfunction or electric shock may happen 17 Do not expose the unit to the moist or corrosive circumstances 18 Under cooling mode please don t set the room temperature t...

Страница 5: ...inage Pipe Connection Pipe Drainage Device Air Inlet Grille With Filter Main Unit Louver Panel 2 2 Rated Working Condition Indoor Side Condition Outdoor Side Condition Dry Bulb Temp C Wet Bulb Temp C...

Страница 6: ...e 5 Sponge 1 To insulate the drain pipe 6 Fastener 4 To fasten the sponge 7 paper pattern for installation 1 Locate the drill hole on ceiling 8 Tapping screw with washer 4 Fix paper pattern 9 Remote c...

Страница 7: ...d noise Even if the distance is 1m 39 3 8 in when there is strong electric wave noise may still occur Unit mm in Fig 3 2 1 1 The unit shall be installed in accordance with national standards or local...

Страница 8: ...t Ordinary polyvinyl chloride sheathed cord 60227 IEC 52 60227 IEC 53 L 250m L 820 1 5ft 2 0 75 2 1 25 2 AWG18 2 AWG16 IEC 60227 5 1 Total length of communication line can t exceed 250m 820 1 5ft 2 Th...

Страница 9: ...s necessary to use shielded wire 3 4 Wiring Requirements Power Cord Size and Air Switch Capacity Model Power Supply MCA A MOP A GMV ND09TS A T U 208 230V 1ph 60Hz 1 15 GMV ND12TS A T U 1 15 GMV ND15TS...

Страница 10: ...43 56 13 16 6 35 1 4 9 52 3 8 GMV ND12TS A T U GMV ND15TS A T U 1200 47 1 4 1252 49 5 16 1403 55 1 4 1443 56 13 16 6 35 1 4 12 7 1 2 GMV ND18TS A T U GMV ND24TS A T U 1200 47 1 4 1252 49 5 16 1403 55...

Страница 11: ...of the hanger bracket The washer fixing plate will prevent the washer from falling 3 The usage of paper pattern Refer to paper pattern of installation for ceiling opening dimension The center of ceili...

Страница 12: ...d then tighten the flaring nut with hand as shown in fig 4 2 1 2 Tighten the flaring nut with torque wrench Fig 4 2 1 3 Use pipe bend when bending the pipe and the bending angle should not be too smal...

Страница 13: ...the drainage pipelines are used for several units the position of pipeline should be about 100mm 4 in lower than the drainage port of each unit In this case thicker pipes should be applied Fig 4 3 1...

Страница 14: ...pe is vertical with the unit the raising height should be less than C Unit mm in Fig 4 3 3 Model A mm in B mm in C mm in GMV ND09TS A T U GMV ND12TS A T U GMV ND15TS A T U GMV ND18TS A T U GMV ND24TS...

Страница 15: ...e water over the electrical components e g water pump etc 2 In case of commissioning finished please energize the IDUs and switch to cooling or dry mode meanwhile the water pump operates you can check...

Страница 16: ...per decorative panel installation could cause the following problems Fig 4 4 1 2 Ensure that its clearance free between decoration panel and ceiling board after installation if not please adjust the b...

Страница 17: ...pipe Fig 4 4 4 2 Adjust the position of panel to make the panel holes fix at the holes on the unit 3 Fix the 4 screws at the two side of panel and then fix the 2 screws in the middle of panel 4 Insta...

Страница 18: ...ircuit breaker for branch circuit according to related regulations and electrical standards 6 Keep cable away from refrigerant pipings compressor and fan motor 7 The communication wires should be sepa...

Страница 19: ...ing operation all indoor units connected to the same outdoor unit system must be kept energized status Otherwise the unit can t operate normally Fig 5 2 1 For units with single phase power supply 1 De...

Страница 20: ...communication bus terminal D1 and D2 as shown in fig 5 3 2 terminal resistor is provided with each ODU 5 4 Connection of Communication Wire for Wired Controller 1 Detach the electric box cover 2 Let...

Страница 21: ...be set as master one and slave one 4 One wired controller can control 16 indoor unitS in maximum at the same time As shown in Fig 5 5 1 1 The type of indoor units must be the same if they are control...

Страница 22: ...Multi Variable Air Conditioners Two way Cassette Indoor Unit 19 Fig 5 5 1...

Страница 23: ...it If the filter is very dirty e g greasy you can clean it using warm water below 45 C that is mixed with mild detergent Then let it dry naturally in cool places 2 If the air conditioner is used in du...

Страница 24: ...Water Temperature Sensor Error L8 Power Insufficiency Protection d7 Humidity Sensor Error C0 Communication Error L9 Quantity Of Group Control Indoor Units Setting Error d8 Water Temperature Error AJ...

Страница 25: ...ked Too heavy heat load of room e g too many people Door or windows is open Inlet and outlet of IDU are blocked Setting temperature is too high or refrigerant leaks Refrigerant is insufficient e g ref...

Страница 26: ......