70
Installation and Maintenance
Service Manual
Step
Procedure
Before disassemble
Turn off the air conditioner and disconnect the
power before disassemble the air conditioner.
1. Remove filter
Hold the handle on the filter, pull it upwards to let
the clasp at the top part of the filter loose, push it
forwards and then the filter can be pulled out.
2.Remove upper and lower guide louver
Push out the plug pin on upper and lower guide
louver, Bend the guide louver with hand and then
separate the guide louver from the crank shaft of
step motor to remove it.
11. Removal Procedure
11.1 Removal Procedure of Indoor Unit
Guide Louver
Filter
Caution: discharge the refrigerant
completely before removal.
Handle