11
Technical Information
Service Manual
2.2 Capacity Variation Ratio According to Temperature
Cooling
Heatling
Outdoor temp.(
°C
)
Capacity ratio(%)
Capacity ratio(%)
20
40
60
80
100
15
120
7
0 2
-5
-7
24
0
-10
-15
5
0
1
Outdoor Temp.(°C)
32 33 34 35 36 37 38 39
43
40 41 42
100
95
105
90
85
80
75
70
65
60
55
50
Condition Cooling
Indoor:DB27°C/WB19°C
Indoor air flow:Super High
Pipe length:5m
Indoor air flow: Super High
Pipe length:5m
Condition Heatin
g
Indoor:DB20°C
/WB15°C
2.3 Cooling and Heating Data Sheet in Rated Frequency
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
Cooling:
Heating:
Rated cooling condition(°C)
(DB/WB)
Model
Pressure of gas
pipe connecting
indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
27/19
35/24
7/9K
0.8 to 1.0
in:8~11
out:11~14
in:75~85
out:37~43
Super High
High
27/19
35/24
12K
0.8 to 1.1
in:10~14
out:11~14
in:69~74
out:38~45
Super High
High
27/19
35/24
18K
0.8 to 1.0
in:8~11
out:11~14
in:75~85
out:37~43
Super High
High
27/19
35/24
24K
0.9 to 1.1
in:8~12
out:11~14
in:75~85
out:37~43
Super High
High
Rated heating condition(°C)
(DB/WB)
Model
Pressure of gas
pipe connecting
indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
20/-
7/6
7/9K
2.4 to 2.6
in:55~65
out:30~37
in:1~3
out:2~5
Super High
High
20/-
7/6
12K
2.4 to 2.6
in:55~65
out:25~32
in:1~3
out:2~5
Super High
High
20/-
7/6
18K
2.2 to 2.4
in:75~85
out:37~43
in:1~3
out:2~5
Super High
High
20/-
7/6
24K
2.2 to 2.4
in:70~85
out:37~43
in:1~3
out:2~5
Super High
High