Setting up a PM400 Planter Monitor for a
3P3025AH-1622
Power up the planter monitor.
Cancel any alarms.
Press the planter setup button.
Change the number of rows to 16 and press enter. See
Change the row spacing to 22 and press enter. See “
Arrow down to the row (plant) icons and press enter.
Arrow to the right and populate the row icons from
17 through 24.
From right to left (highest row number to lowest row
number) blank rows 22, 20, 16, 14, 12, 8, 6, and 4, then
press enter.
Blanking a row means the icon is a blank box and the
row number goes away. Row numbers to the right will
change as rows are blanked. This is normal. Be sure to
press enter to save row configuration for this mode.
Press the operate button to save the setup.
Power down the planter monitor.
Power up the planter monitor.
There should be no alarms.
There should only be 16 rows shown on the operating
screen.
If this is the only planter this planter monitor is used on,
set up mode 2 and mode 3 in the same way.