![GREAT PLAINS Yield-Pro 3P3025AH Скачать руководство пользователя страница 135](http://html.mh-extra.com/html/great-plains/yield-pro-3p3025ah/yield-pro-3p3025ah_operators-manual_2259521135.webp)
3P3025AH
Appendix C - Monitor Setup, PM400
Great Plains
| 411-332M | 2019-02-19
131
Setting up the PM400 Planter Monitor
According to Planter Configuration
The PM400 planter monitor has been configured for the
planter at the factory.
If the configuration information in the planter monitor is
lost, the information specific to the planter must be
entered again. The following instructions are divided
according to planter configuration.
Setting up a PM400 Planter Monitor for a
3P3025AH-0836, -0838, or -0840
Power up the planter monitor.
Cancel any alarms.
Press the planter setup button.
Change the number of rows to 8 and press enter. See
Change the row spacing to match the planter (36, 38, or
40 in) and press enter. See “
Arrow down to the row (plant) icons and press enter.
Arrow to the right and populate the row icons from
9 through 21.
Note: Rows 22, 23, and 24 will drop off.
From right to left (highest row number to lowest row
number) blank rows 20, 18, 17, 16, 15, 14, 13, 10, 9, 6,
5, 4, and 2, then press enter.
Blanking a row means the icon is a blank box and the
row number goes away. Row numbers to the right will
change as rows are blanked. This is normal. Be sure to
press enter to save row configuration for this mode.
Press the operate button to save the setup.
Power down the planter monitor.
Power up the planter monitor.
There should be no alarms.
There should only be 8 rows shown on the operating
screen.
If this is the only planter this planter monitor is used on,
set up mode 2 and mode 3 in the same way.