![GRAUPNER ultra duo plus 80 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/graupner/ultra-duo-plus-80/ultra-duo-plus-80_operating-manual_2258153055.webp)
Operating Manual ULTRA DUO PLUS 80
55
Battery:
Charge current / power
2x 0.1 - 20 A / 2x max. 500 W with external power supply 11...28 V DC
Discharge current / power
2x 0.1 - 10 A / 2x max. 50 W with external power supply 11...28 V DC
20 battery memories per output
Ni-Cd & Ni-MH batteries:
Cell count
1 - 18 cells - charge, discharge, cycle
Charging programs
automatic, normal, linear and reflex
peak: NiCd 5 - 25 mV/cell, NiMH zeroPeak, 3 - 15 mV/cell
Trickle charge
Off, < 500 mA, automatic (1/20 charge current)
Cycle
1 - 10 cycles, interval 1 - 30 min. variable
Sequence charge
→
discharge, discharge
→
charge, variable
Max. capacity
10 - 150%
Lithium batteries:
Cell count
1-7 cells - charge, discharge, storage mode
Cell voltage
3,3V (LiFe), 3,6 V (LiIo), 3,7 V (LiPo)
Max. capacity
10 - 120%
Charge rate
1 - 5 C
TCS capacity
10 - 100%
Lead-acid batteries:
Cell count
1-12 cells - charge, discharge, storage mode
Cell voltage
2 V
Miscellaneous:
Operating voltage range, DC input:
11.0 to 28 V
Car battery required
12 V, min. 60 Ah
Mains PSU for DC input:
12 - 28 V, min. 30 A stabilised
1)
No-load current drain
approx. 210 mA
Low-voltage cut-off
approx. 10.7 V
Balancer socket:
EH, 1...7 LiPo/LiIo/LiFe cells
Balancer current max.
approx. 350 mA LiPo/LiIo/LiFe
Temperature sensor:
10-60° C / 50-150° F
Safety timer:
20 - 300 min., off
Weight:
approx. 1300 g
Dimensions approx. (WxDxH)
172 x 178 x 70 mm
All data measured using a car battery voltage of 12.5 V.
The stated values are approximate, and may vary according to the condition and temperature of the battery etc.
1)
The charger can only operate correctly in conjunction with a mains PSU if many requirements are fulfilled, including ripple voltage, voltage stability, stability under load, etc. Please use only those PSUs
which we specifically recommend.
20.Specification