![GRAUPNER ultra duo plus 80 Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/graupner/ultra-duo-plus-80/ultra-duo-plus-80_operating-manual_2258153038.webp)
38
Operating Manual ULTRA DUO PLUS 80
Connect a battery
+
_
LiPo with Balancer
Channel1
1S
3S
2S
GND
black
Balancer connection
NOTE:
the black wire of the
balancer plug (-) must al-
ways be connected to PIN0
(GND), regardless of the number of
cells in the pack, and thus the num-
ber of wires at the balancer plug.
4S
EH
5S
6S
7S
Temperature sensor (option)
+
_
WARNING:
never connect your batteries as shown in the pictures above, as this may damage the battery or charger.
Fire or explosion hazard!
The battery charger is equipped with a large number of protective and monitoring systems designed to check the machine’s individual functions and
electronics. If any limit value is exceeded, or if the charger is operated incorrectly, it generates the error messages described in Chapter 19; it may also
terminate the charge process (e.g. if the car battery is almost fl at). Nevertheless you should always avoid connecting the batteries as shown in the illustra-
tions below, since - for example - under certain circumstances a defective battery may not trigger a warning, and this may result in damage to the charger.
The balancer sockets are polarised; watch out for the lateral lugs. Never use force to insert a connector; plugs should slide smoothly into sockets.
Most cables are colour-coded: black (brown) wire = negative (-) terminal; red wire = positive (+) terminal.
XH - PQ - TP
XH - PQ - TP
_
EH