GRAUPNER HoTT General Engine-Module 2-6 S Скачать руководство пользователя страница 8

Parameter

Display page

Description

Setup

Warning Time

Page 2 – page 24

Warning time

OFF, 5, 10, 15, 20, 
25, 30 sec.

Repeat Time

Page 2 – page 24

Repeat time

Always, 1, 2, 3, 4, 5 
Minuten, One Time

Signal Tone

Page 2 – page 24

Signal tone

A - Z

Save Sensor

Page 1

saves the setup to the General 
Engine-Module

OK / NO

Factory Set

Page 1

Reset to factory settings

OK / NO

If you wish to carry out an adjustment (point 6.1 to 6.15) you must use the INC (

) or DEC (

) buttons 

above the screen to select „page 1 - Save Sensor“. Simultaneously pressing the INC and DEC buttons 
(

SET

) switches the parameter to be adjusted to inverse video (white on black); this indicates that it can be 

programmed: pressing the INC (

) button at this point increases the value to YES. When the adjustment is 

complete, save the selected setting by pressing the INC and DEC buttons (

SET

) simultaneously; the dark 

background now disappears in order to con

fi

 rm this action.

If you do not want to save the adjustments, select NO.

Warning: 

•  Do not carry out any programming work on the sensors while the model is 

fl

 ying, otherwise there is a real 

 

risk that your model will 

fl

 y out of control while you are not concentrating on it!

•  If your model is 

fi

 tted with two or more receivers, it is absolutely essential that you do not carry out pro-

 

gramming work during a 

fl

 ight, as this can alter the settings in the receivers to which no telemetry equip-

 

ment is connected; in the worst case this could result in the model crashing.

 

For this reason always carry out programming on the ground, and check that only the receiver with con-

 

nected sensors is powered on.

07

                                                                                   33610 General Engine-Module - Graupner HoTT 2.4

    

Содержание HoTT General Engine-Module 2-6 S

Страница 1: ...ge sensor 1 Page 4 08 6 4 Minimum temperature sensor 1 Page 5 08 6 5 Maximum temperature sensor 1 Page 6 09 6 6 Minimum cell voltage sensor 2 Page 7 09 6 7 Maximum cell voltage sensor 2 Page 8 09 6 8...

Страница 2: ...e resulting operation is explicitly mentioned at the appropriate point in the instructions see also point 5 For full functionality additional sensors are necessary Informations available Setup Battery...

Страница 3: ...easuring power system currents please note that the voltage fall off at the shunt resistors can place an increased load on the speed controller and on the speed controller s capacitors in particular F...

Страница 4: ...ansmitter display TX There may be a slight delay in the screen s response to inputs since all the settings are transmitted directly to the receiver by wireless means Operation with the SMART BOX The S...

Страница 5: ...tage of the LiXX battery connected to socket 6 Min Minimum single cell voltage of the LiXX battery connected to socket 6 since the start Max Maximum single cell voltage of the LiXX battery connected t...

Страница 6: ...preset blade number Max Maximum RPM since the start Min Minimum RPM since the start With connected speed sensor the current engine rpm is determi ned Therefore you must first specify how many blades...

Страница 7: ...arameters can be set separately for all displays Warning Time sets whether and how long the warning signal is activated when reaching a certain value for each display screen Repeat Time sets how often...

Страница 8: ...to YES When the adjustment is complete save the selected setting by pressing the INC and DEC buttons SET simultaneously the dark background now disappears in order to confirm this action If you do not...

Страница 9: ...1 C steps Factory setting 0 C Signal Tone F 6 1 Minimum Cell Voltage Page 2 The voltage of the battery connected to socket 6 is monitored Warning threshold set between 2 5 and 4 2 V 0 1 V steps Factor...

Страница 10: ...1 V steps ber wacht den an Buchse 7 ber Sensor 2 angeschlossen Akku Factory setting 30 V Signal Tone K 6 8 Minimum Temperature Sensor 2 Page 9 The temperature of the sensor 2 socket 7 is monitored War...

Страница 11: ...ption of the connected equipment is measured You can program the max used capacity at which the alarm should be triggered so you have enough remaining capacity for a save landing Monitors the battery...

Страница 12: ...able from 1 to 6 blades The warning threshold is adjustable from 0 to 200 000 rpm 1 blade with 10 rpm steps Factory setting 200 rpm Signal Tone T 6 15 Maximum RPM Page 16 Monitors the optional speed s...

Страница 13: ...fy how many blades or magnets with sensor order no 33516 the propeller rotor has to get the correct rpm In addition you can set the minimum engine speed at which the alarm should be triggered Blade Nu...

Страница 14: ...y socket T connect to telemetry so cket of the receiver to drive motor OUT Note the permitted maximum current for the lower JR so ckets is 5 A This socket may only be used if the model s power system...

Страница 15: ...ammed under STOP until such time as the current drain falls back below the set value The current is then raised again to the selected throttle position etc This means that you can fly at one throttle...

Страница 16: ...1 S page 7 Min voltage sensor 2 page 5 Min temperature sensor 1 T page 15 Minimum RPM page 9 Min temperature sensor 2 U page 6 Max temperature sensor 1 page 10 Max temperature sensor 2 page 4 Max volt...

Страница 17: ...metry display Please note these menus can only be selected if the receiver is already switched on After you switch the receiver on note that it may take several seconds before the display becomes acti...

Страница 18: ...second connector a suitable receiver battery to power the update process is connected Caution Plug in the receiver battery after pushing the Program button see point 10 2 or use a switch harness 17 3...

Страница 19: ...tter update file instead of receiver file then the pop up window Product code error will appear and you will not be able to start the update procedure Press the Program button in the software Wait bri...

Страница 20: ...1 mAh Temperature Sensor 1 2 range 20 C 200 C resolution 1 C Voltage Sensor 1 2 max 60 00 V DC resolution 10 mV accurancy 1 LiXX cell voltage Max number of cells 6 resolution 10 mV accurancy 1 RPM ran...

Страница 21: ...t dispose of it in the or dinary domestic waste The correct method of disposal is to take it to your local collection point for recycling electrical and electronic equipment The symbol shown here whic...

Страница 22: ...94 96 73230 Kirchheim Teck Allemagne accorde sur ce produit une garantie de 24 mois partir de la date d achat La garantie prend effet uniquement sur les vices de fonc tion nement et de mat riel du pr...

Страница 23: ..._________________________________________________________________________________ _____________________________________________________________________________________ ________________________________...

Страница 24: ...st supplier We accept no liability for printing errors Sous r serve de modifications et de possibilit de livraison Livraison uniquement au travers de magasins sp cialis s en mod lisme Nous pourrons vo...

Отзывы: