GRAUPNER HoTT General Engine-Module 2-6 S Скачать руководство пользователя страница 2

THANK YOU

for purchasing the General Engine-Module for the Graupner HoTT 2.4 system. 
If you do not have the Graupner HoTT 2.4 radio system this product will not work. This product is not com-
patible with any other 2.4GHz radio system.
Please read through this entire manual before you attempt the installation and usage of your Graupner HoTT 
General Engine-Module! 

These operating instructions are part of this product. They contains important notes to the operation and 
handling. Please take this into consideration when you pass on the product to third parties. Neglect of the 
operating instructions and the safety instructions lead to expiring the warranty.
Graupner constantly work on the advancement of all remote control systems; changes of the scope of deli-
very in form, technology and equipment we must reserve ourselves therefore. Please have understanding
for the fact that from data and illustrations of this operating instructions no requirements can be derived.

Please keep these instructions for further reference! 

DESCRIPTION

1. 

The Graupner-HoTT General Engine-Module enables the wireless monitoring of for example the battery 
voltage, power consumption, motor rpm, or fuel consumption of the model in real time. The General Engine-
Module can be programmed directly with all HoTT transmitters with integrated telemetry in the transmitter 
display (some models such as MC-24 with update or modi

fi

 cation).

The following transmitters must be programmed via SMART-BOX order No. 33700:

 mx-12 HoTT order 

No. 4754, mx-16 HoTT order No. 4755, and mx-22 No. 4801/4802, mc-19 No. 4821 and mc-22 No. 4818 
after conversion to HoTT. This differentiation between the transmitter models and the resulting operation is 
explicitly mentioned at the appropriate point in the instructions (see also point 5).
For full functionality, additional sensors are necessary.

Informations available - Setup: 

Battery voltage (total - single cell), Min./Max. voltage, Min./Max. cell voltage
Maximum current, used capacity
Temperature (optional Sensor 1/Sensor 2), Min./Max. Temperature 
Fuel level, Min. fuel level, 
RPM, Minimum/ Maximum RPM

Note: 

Any settings you make on the Transmitter or SMART-BOX will be stored in the General Engine-

Module only!

Since the General Engine-Module can be updated via the USB connection, you always have the latest soft-
ware and can utilize future functions or languages. Firmware updates for the General Engine-Module can 
be transferred via the DATA or telemetry interface in conjunction with a PC running Windows XP, Vista or 7. 
For this you also require the USB interface, Order No. 7168.6, the adapter lead, Order No. 7168.6A  and a 
Y-cable Order No. 3936.11 which are available separately.
The programs and 

fi

 les required for this are available from www.graupner.de in the Download area for the 

corresponding products. 

2.  MOUNTING THE MODULE IN THE PLANE

Mount the General Engine-Module at an appropriate location in the model. The best way to 

fi

 x the General 

Engine-Module with the mounting tabs or double sided tape on a wind-protected frame in the model, the 
orientation of the sensor is not important.

3. CONNECTION OF SENSORS

The consumed current and capacity is measured only on connection 1 (IN) and 8 (OUT). Therefore, the  
main battery for the motor (electric model - G3.5 connector) or the transmitter battery (Nitro model - JR con-
nector) must be connected to this connection. Use a connector system to replace the battery easily. If you 
use a LIXX battery, the balancer can be plugged into socket 6 to monitor the individual cell voltage. 

01

                                                                                   33610 General Engine-Module - Graupner HoTT 2.4

    

Содержание HoTT General Engine-Module 2-6 S

Страница 1: ...ge sensor 1 Page 4 08 6 4 Minimum temperature sensor 1 Page 5 08 6 5 Maximum temperature sensor 1 Page 6 09 6 6 Minimum cell voltage sensor 2 Page 7 09 6 7 Maximum cell voltage sensor 2 Page 8 09 6 8...

Страница 2: ...e resulting operation is explicitly mentioned at the appropriate point in the instructions see also point 5 For full functionality additional sensors are necessary Informations available Setup Battery...

Страница 3: ...easuring power system currents please note that the voltage fall off at the shunt resistors can place an increased load on the speed controller and on the speed controller s capacitors in particular F...

Страница 4: ...ansmitter display TX There may be a slight delay in the screen s response to inputs since all the settings are transmitted directly to the receiver by wireless means Operation with the SMART BOX The S...

Страница 5: ...tage of the LiXX battery connected to socket 6 Min Minimum single cell voltage of the LiXX battery connected to socket 6 since the start Max Maximum single cell voltage of the LiXX battery connected t...

Страница 6: ...preset blade number Max Maximum RPM since the start Min Minimum RPM since the start With connected speed sensor the current engine rpm is determi ned Therefore you must first specify how many blades...

Страница 7: ...arameters can be set separately for all displays Warning Time sets whether and how long the warning signal is activated when reaching a certain value for each display screen Repeat Time sets how often...

Страница 8: ...to YES When the adjustment is complete save the selected setting by pressing the INC and DEC buttons SET simultaneously the dark background now disappears in order to confirm this action If you do not...

Страница 9: ...1 C steps Factory setting 0 C Signal Tone F 6 1 Minimum Cell Voltage Page 2 The voltage of the battery connected to socket 6 is monitored Warning threshold set between 2 5 and 4 2 V 0 1 V steps Factor...

Страница 10: ...1 V steps ber wacht den an Buchse 7 ber Sensor 2 angeschlossen Akku Factory setting 30 V Signal Tone K 6 8 Minimum Temperature Sensor 2 Page 9 The temperature of the sensor 2 socket 7 is monitored War...

Страница 11: ...ption of the connected equipment is measured You can program the max used capacity at which the alarm should be triggered so you have enough remaining capacity for a save landing Monitors the battery...

Страница 12: ...able from 1 to 6 blades The warning threshold is adjustable from 0 to 200 000 rpm 1 blade with 10 rpm steps Factory setting 200 rpm Signal Tone T 6 15 Maximum RPM Page 16 Monitors the optional speed s...

Страница 13: ...fy how many blades or magnets with sensor order no 33516 the propeller rotor has to get the correct rpm In addition you can set the minimum engine speed at which the alarm should be triggered Blade Nu...

Страница 14: ...y socket T connect to telemetry so cket of the receiver to drive motor OUT Note the permitted maximum current for the lower JR so ckets is 5 A This socket may only be used if the model s power system...

Страница 15: ...ammed under STOP until such time as the current drain falls back below the set value The current is then raised again to the selected throttle position etc This means that you can fly at one throttle...

Страница 16: ...1 S page 7 Min voltage sensor 2 page 5 Min temperature sensor 1 T page 15 Minimum RPM page 9 Min temperature sensor 2 U page 6 Max temperature sensor 1 page 10 Max temperature sensor 2 page 4 Max volt...

Страница 17: ...metry display Please note these menus can only be selected if the receiver is already switched on After you switch the receiver on note that it may take several seconds before the display becomes acti...

Страница 18: ...second connector a suitable receiver battery to power the update process is connected Caution Plug in the receiver battery after pushing the Program button see point 10 2 or use a switch harness 17 3...

Страница 19: ...tter update file instead of receiver file then the pop up window Product code error will appear and you will not be able to start the update procedure Press the Program button in the software Wait bri...

Страница 20: ...1 mAh Temperature Sensor 1 2 range 20 C 200 C resolution 1 C Voltage Sensor 1 2 max 60 00 V DC resolution 10 mV accurancy 1 LiXX cell voltage Max number of cells 6 resolution 10 mV accurancy 1 RPM ran...

Страница 21: ...t dispose of it in the or dinary domestic waste The correct method of disposal is to take it to your local collection point for recycling electrical and electronic equipment The symbol shown here whic...

Страница 22: ...94 96 73230 Kirchheim Teck Allemagne accorde sur ce produit une garantie de 24 mois partir de la date d achat La garantie prend effet uniquement sur les vices de fonc tion nement et de mat riel du pr...

Страница 23: ..._________________________________________________________________________________ _____________________________________________________________________________________ ________________________________...

Страница 24: ...st supplier We accept no liability for printing errors Sous r serve de modifications et de possibilit de livraison Livraison uniquement au travers de magasins sp cialis s en mod lisme Nous pourrons vo...

Отзывы: