33610 General Engine-Module - Graupner HoTT 2.4
10
6.9. Maximum Temperature Sensor 2 (Page 10)
The temperature of the sensor 2 (socket 7) is monitored. Warning
threshold set between -20 and 200° C (1° C steps).
Factory setting: 100° C, Signal Tone: I
6.10. Maximum Current (Page 11)
If the module is connected between the power supply and the motor or
receiver battery, the power consumption of the connected equipment is
measured. You can program the maximum peak current at which the
alarm should be triggered, to avoid to overload the motor or battery.
Monitors the battery connected to port 1. The warning threshold is ad-
justable up to 50 A in 0.1 A steps.
Factory setting: 40 A, Signal Tone: W
6.11. Maximum used Capacity (Page 12)
If the module is connected between the power supply and the motor or
receiver battery, the power consumption of the connected equipment
is measured. You can program the max. used capacity at which the
alarm should be triggered, so you have enough remaining capacity for
a save landing.
Monitors the battery connected to port 1. The warning threshold is ad-
justable up to 30.000 mAh in 0.1 A steps.
Factory setting: 2000 mAh, Signal Tone: V
6.12. Minimum Voltage socket 1 (Page 13)
The voltage of the battery connected to socket 1 is monitored. Warning
threshold set between 0 and 80.0 V (0.1 V steps).
Factory setting: 5.0 V, Signal Tone: P
Max. Sensor2 Temp
>Set Warning :
Temperature :
Warning Time :
Repeat Time :
Signal Tone :
Sensor 2
:
page 10
100°C
Off
Always
I
00°C
DEC
INC
Max. Current
>Set Warning :
Max Current :
Warning Time :
Repeat Time :
Signal Tone :
Current :
page 11
40A
Off
Always
W
0.0A
DEC
INC
Max. Used Capacity
>Set Warning :
Max Capacity :
Warning Time :
Repeat Time :
Signal Tone :
Capacity :
page 12
2000mA
Off
Always
V
0 mA
DEC
INC
Min. Power Voltage
>Set Warning :
Min Voltage :
Warning Time :
Repeat Time :
Signal Tone :
page 13
5.0V
Off
Always
A
DEC