background image

8.

Switching commands

18

The input of the switching commands applies to all types of assignment

Switching commands without date assignment, always in block 00, 
always with priority 0 (standard switching commands).

Switching commands with single date, see Section 9.1

Switching commands with date range, see Section 9.2

Pulse switching commands, see Section 11

Cycle switching commands, see Section 12

You determine the switching times and the switching state for the
relevat channel.
Symbol      ON;      OFF

Switching commands for each channel the same, all ON or all OFF

Switching commands for each channel different, ON and OFF

Note:

In the case of multi-channel clocks, channel 1 is always offered.
The switching state can also be deactivated for each channel.
No symbol = no switching.

Select free memory location:

Press the Prog. Key 1x.
– –.– –
– –  – –

Setting the switching times:

Hours with the h key
Minutes with the m key

Содержание talento 812

Страница 1: ...c switchover 11 7 2 2 cHA Weekday related switchover 12 7 2 3 no No switchover 13 8 Switching commands 14 9 Date 16 9 1 Single date without with year 17 9 2 Date range without with year 18 10 Priority...

Страница 2: ...xceeds the currently valid requirements of the appropriate EN standards In individual cases check whether additional protection measures are still necessary e g the installation of appropriate compone...

Страница 3: ...Putting into operation The time and date have been set at the factory The time switch is in power save mode Only the colon flashes Press any key The time switch is active It shows the time day of the...

Страница 4: ...ay 3 Summer time winter time switchover Select pulse Reset Select cycle Current date time settings Begin program input Send receive IR Priority Delete up to for date range Calendar day Calendar month...

Страница 5: ...n Automatic operation Switching state Channel 2 Channel 3 Channel 4 Hours Year number 1234567 Day of the week Month US day Pulse seconds Cycle seconds Automatic operation Cycle Pulse DCF 77 Radio rece...

Страница 6: ...der 6 2 Priority Switching commands with a date assignment can be occupied with different priorities If you start with a date when entering the program a new block number and priority 2 are always off...

Страница 7: ...ion Restore with the key Prog and 7 Day key The switching program in the foreground can be changed as required The saved and the current switching programs can be used alternately with the Change func...

Страница 8: ...h to time switch from control section to control section without mains voltage The switching programs are read out from one time switch and are transferred to the next one see the talento taxxi operat...

Страница 9: ...now transferred to the relevant time switch control section via the infrared interface Refer to the talento dialog manual Note Software and accessories can be ordered separately talento taxxi set Art...

Страница 10: ...er via the IR interface Transfer the program again There may be read write errors Er 01 If the battery voltage is too low 6 6 2 Lithium battery service life type see Technical data If the battery volt...

Страница 11: ...ee Section 7 2 2 You enter the summer time end date valid for your location country e g the first Sunday in April of the current year start of summer time the last Sunday in October of the current yea...

Страница 12: ...he time switch receives the time signal DCF 77 it may be necessary depending on the location for the display to be adjusted You have the possibility of adjusting the time by up to 2 hours with respect...

Страница 13: ...y calendar year Setting and changing the time With the h key hours With the m key minutes Press the key 1x The input is completed The display shows the date and time Note The day of the week is automa...

Страница 14: ...summer time e g 28 03 in the year 1999 and AU are displayed Press the key 1x flashes End of summer time e g 31 10 in the year 1999 and AU are displayed Press the key 1x The input is completed The iden...

Страница 15: ...e Day key Calendar month with the Month key Press the key 1x flashes Individual summer time end setting Calendar day with the Day key Calendar month with the Month key Press the key 1x The input is co...

Страница 16: ...til no appears The time switch operates with the calendar but without automatic switchover The manual switchover function can always be activated with the key 1h Press the key 1x The input is complete...

Страница 17: ...ection 11 Cycle switching commands see Section 12 You determine the switching times and the switching state for the relevat channel Symbol ON OFF Switching commands for each channel the same all ON or...

Страница 18: ...ng state With the 1 0 key for each channel separately select ON OFF Briefly press the Prog key 1x The switching command is saved A free memory location is displayed for additional inputs or Press the...

Страница 19: ...tching commands without date assignment always in block 00 always with priority 0 see Section 10 Several entries to which particular switching times are assigned can be in one block These entries are...

Страница 20: ...Month key Calendar year with the Year key Change priority see Section 10 Press the Prog key only briefly This input is saved A free memory location is displayed for additional inputs Have you made all...

Страница 21: ...Calendar month with the Month key Calendar year with the Year key Change priority see Section 10 Press the key 1x flashes Entered the required end date without or with year Calendar day with the Day...

Страница 22: ...is displayed for further entries Have you made all date entries for this block If so enter the relevant switching commands see section 8 or Press the key 1 x The input is completed The display shows t...

Страница 23: ...an be changed between 1 and 9 The switching command with the higher priority is executed first Example Within a date range e g 9 6 to 30 6 priority 3 it is possible to assign priority 4 or higher to a...

Страница 24: ...imes are 01 99 seconds or 01 99 minutes A pulse switching command consists of Start time and ON or OFF switching duration Example Start time Monday to Friday 09 00 ON switching duration 10 seconds ON...

Страница 25: ...om 01 99 Note If the key is pressed for longer adjustment takes place in steps of 05 Press the Prog key 1x only briefly The switching command is saved A free memory location is displayed for additiona...

Страница 26: ...nsists of Start time Cycle duration ON switching duration pause ON switching duration If you assign no End time to a cycle switching command it operates continuously In practice an End time will in mo...

Страница 27: ...duration 10 minutes Select free memory location Press the Prog key 1x Enter as required Switching command weekday s switching state see Section 8 Single date without with year see Section 9 1 Date ran...

Страница 28: ...05 Setting the ON switching duration 01 99 This can never be greater than the previsously set cycle time Press the key step wise Press the Prog key 1x only briefly The switching command is saved A fre...

Страница 29: ...ntering the program is displayed block number 00 priority 0 Read contents of block 00 Press the Prog key only briefly step wise The contents are displayed in turn If a cycle switching command is displ...

Страница 30: ...ate appears in the display With the symbol key read the end date and switch back to the start date If a cycle switching command is displayed appears in the display Press the key 1x and read the ON or...

Страница 31: ...e date without with year see Section 9 1 Date range without with year see Section 9 2 Priority see Section 10 Pulse switching commands see Section 11 Cycle switching commands see Section 12 13 3 Delet...

Страница 32: ...f extreme faults The electronics is brought to a defined state but all data is preserved Press the Prog key 2x The number of free block numbers and the number of free memory locations is displayed Pre...

Страница 33: ...ing state The next switching command in the program is executed again automatically FIX continuous operation FIX Continuous ON FIX Continuous OFF You change m a n u a l l y the current switching state...

Страница 34: ...IP 20 Captive screw terminals Yes Dimensions H x W x D mm Distributor cut out mm Weight g approx Connection Power consumption Switching capacity Ohmic load VDE IEC Inductive load cos phi 0 6 Incandes...

Отзывы: