Zodiak Installation and Service Manual
95
Setting IP Addresses
6.
Enter 255.255.255.0 in the
Subnet Mask
field unless directed otherwise by
your system administrator.
7.
In the
Gateway IP
field, enter the IP address of the external gateway as
directed by your System Administrator.
8.
In the
Panel LAN
section, in the
IP Address
field, set the correct IP address
for the Video Processor frame on the Panel LAN.
9.
Enter 255.255.255.0 in the
Subnet Mask
field unless directed otherwise by
your system administrator.
CAUTION
When you are done filling in the addresses, double-check and record the
values. This is the only access to the frame and if these IP address are lost or
entered incorrectly, communication cannot be re-established with a web
browser. In this case, you will need to run an emergency boot procedure
using floppy disk to restore the default IP addresses. See
Section 5-Troubleshooting and Diagnostics
10.
After you have confirmed and recorded the new IP addresses, press the
Save New Settings
button.
11.
Reset the frame by pushing the Video Processor frame
Reset
button on
the front of the Control Processor/DSK/Still Store module (
Figure 65. Frame Reset Button Location
Identify New IP Addresses in Menu Panel
Once the new IP addresses are set for the Main panel and Video Processor
frame, the new IP addresses must be entered into the Zodiak Menu for
proper communication with the Menu panel. To identify the frame and
Main panel addresses in the Menu panel:
1.
Run the Zodiak Menu application.
2.
Touch the
Eng Setup
menu selection button.
3.
Touch the
System
menu selection button at the bottom of the screen.
4.
Touch the
Config
selection button in the
System
pane on the left of the
screen (
).
ON
OFF
Reset Button
Boot Switch
8125_00_11_r3
Control Processor/DSK/Still Store Module
Floppy
Disk Drive