Scanner Calibration
Before beginning calibration, clean the scanner glass and scanner table surface. Any dust
or dirt on this surface may affect calibration results and resulting image quality.
Check that the calibration sheet is free of any dust or dirt.
The calibration procedure will take some time. Do not switch off the scanner while
calibration is underway. Accidentally switching off the scanner may result in damage
that requires servicing.
(1)
Connect the scanner to the computer. Switch on the scanner, then switch on the PC.
(2)
Launch the
Scanner Adjustment
program
(as described earlier).
(3)
Select
Model Setup
on the
Scanner
menu.
(4)
Select the connected scanner and click the
OK
button.
(5)
Select
Calibration
on the
Scanner
menu.
(6)
Select
All
in
Calibration
and click the
Execute
button.
(7)
The following message is displayed. Insert the calibration sheet into the scanner as
instructed.