SERVICE AND TECHNICAL SUPPORT
MANUAL
Single Stage, PSC Blower Motor
35” Tall, High Efficiency Condensing Gas Furnace
WFAR080B048 (B Series Only)
WFAR (All C Series)
Save this manual for future reference.
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The
signal
words
DANGER,
WARNING
,
CAUTION
, and
NOTE
are used to identify levels of
hazard seriousness. The signal word
DANGER
is
only used on product labels to signify an immediate
hazard. The signal words
WARNING
,
CAUTION
,
and
NOTE
will be used on product labels and
throughout this manual and other manual that may
apply to the product.
DANGER
-- Immediate hazards which will result in
severe personal injury or death.
WARNING
-- Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION
-- Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE
-- Used to highlight suggestions which will
result in enhanced installation, reliability, or
operation.
!
WARNING
Signal Words in Manuals
The signal word
CAUTION
is used throughout
this manual in the following manner:
!
CAUTION
Signal Words on Product Labeling
Signal words are used in combination with
colors and/or pictures or product labels.
The signal word
WARNING
is used throughout
this manual in the following manner:
Safety--alert symbol
When you see this symbol on the unit and in
instructions or manuals, be alert to the
potential for personal injury.
TABLE OF CONTENTS
START--UP, ADJUSTMENT, AND SAFETY CHECK
3
. . . .
GENERAL
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRIME CONDENSATE TRAP WITH WATER
3
. . . . . . . . . .
PURGE GAS LINES
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ADJUSTMENTS
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHECK INLET GAS PRESSURE
4
. . . . . . . . . . . . . . . . . . . .
ADJUST MANIFOLD PRESSURE
5
. . . . . . . . . . . . . . . . . . .
ADJUST TEMPERATURE RISE
6
. . . . . . . . . . . . . . . . . . . . .
ADJUST BLOWER OFF DELAY (HEAT MODE)
7
. . . . . . .
BLOWER OFF DELAY JUMPER POSITIONS
7
. . . . . . . . .
ADJUST COOLING AIRFLOW
7
. . . . . . . . . . . . . . . . . . . . . .
ADJUST THERMOSTAT HEAT ANTICIPATOR
7
. . . . . . . .
CHECK SAFETY CONTROLS
7
. . . . . . . . . . . . . . . . . . . . . .
CHECKLIST
7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ALTITUDE DERATE MULTIPLIER.
8
. . . . . . . . . . . . . . . . . .
GAS RATE (CU FT./HR)
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
ORIFICE SIZE AND MANIFOLD PRESSURE
11
. . . . . . . . .
AIR DELIVERY -- CFM
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SERVICE AND MAINTENANCE PROCEDURES
14
. . . . . .
PRESSURE SWITCHES
14
. . . . . . . . . . . . . . . . . . . . . . . . . . .
CLEANING HEAT EXCHANGERS
20
. . . . . . . . . . . . . . . . . . .
SEQUENCE OF OPERATION
24
. . . . . . . . . . . . . . . . . . . . . .
PARTS REPLACEMENT INFORMATION GUIDE
28
. . . . . .
MODELS
WFAR040A030C
WFAR060B048C
WFAR080B048B
WFAR080B048C
WFAR080C060C
WFAR100C048C
WFAR100C060C
WFAR120D060C
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program.
For verification of certification for individual
products, go to www.ahridirectory.org .