www.graf.info
20 / 45
4.
Assembly of the switch cabinet
900
585
845
300
Exterior column for outdoor installation
2-10 PE
Exterior cabinet for outdoor installation
12-18 PE
4.5
Assembling the exterior cabinet
The plastic column intended for outdoor installation should be sunk into the ground up to the mark on the
front of the cabinet. A ditch of a sufficient depth should be dug for this (see Figure on page 7). In order to
avoid overheating in summer, a site must be chosen in which the cabinet is not continuously exposed to
direct sunlight.
A ditch with the following measurements should be
prepared at the planned site:
Exterior column
Exterior cabinet
Length approx. 360 mm
Width approx. 360 mm
Depth approx. 600 - 640
mm
Length approx. 585 mm
Width approx. 315 mm
Depth approx. 600 - 640
mm
The empty pipe and the air hoses must be routed
into the prepared ditch.