Lighting Instructions
20
3A1319K
ThermoLazer 300
TC
/ProMelt
1. Turn gas safety valve to “OFF”.
2. Close kettle manual shut-off valve (KK) when
finished heating with kettle burners. Close manual
shut-off valve on propane tank when finished
melting and heating thermoplastic material.
NOTE:
The kettle gas burner can be lit manually with a
small torch (for example: DOT 39 NRC 228/286 Cylin-
der with #3 torch tip) if the battery powered pulse ignitor
fails to light the pilot.
Torch Lighting Instructions
1. Open manual shut-off valve on propane tank
located at front of unit.
2. Remove external torch from holder.
3. Slowly open torch flame adjusting valve and use
striker to ignite flame.
4. Adjust flame to desired length.
ti14128a
ti14125a
KK
ti14127a
ti14138a
ThermoLazer 300
TC
shown
ti14139a
ti14141a
Содержание ThermoLazer
Страница 39: ...Notes 3A1319K 39 Notes ...