Bead Dispenser Box
3A1319K
31
13. Move ControlFlow Gate Valve Lever (S) to raised
position and fill screed box with melted
thermoplastic material.
NOTE:
The material gate is adjustable. The gate is
factory set at a 0.5 in. (1.3 cm) gap. You can
increase this gap for more material flow or decrease
the gap for less material flow.
14. Do not overfill material in kettle. Overfill would be
material higher than 5 in. (13 cm) below top of
kettle.
15. Avoid bumping or impacting the unit to prevent spill-
age or splashing of hot material.
ProMelt Overheating Protection
This unit has a built-in protective device to prevent dam-
age from overheating. The kettle burners may automati-
cally shut down if excessive temperatures are reached.
If this happens, allow the unit to cool down for 20-30
minutes or until main kettle burners (2) reignite and
resume operation.
Bead Dispenser Box
(All ThermoLazer units)
The Bead Dispenser Box has multiple doors which can
be opened and closed to allow beads to be dispensed at
desired width patterns.
Bead flow rate can be adjusted using the Bead Flow
Rate Lever on the outside of the Bead Dispenser Box.
Adding Beads to
SplitBead Hopper
Single Bead Application
(ThermoLazer 200/200
TC
)
1. Open SplitBead hopper door.
2. Fill hopper with beads.
Close and lock hopper door. Do not allow beads to
remain in hopper, hoses or bead dispenser for an
extended period of time. Beads will absorb moisture,
bond to adjacent beads and harden.
Single Bead Application
(ThermoLazer 300
TC
/ProMelt)
1. Unlock and open SplitBead hopper door.
2. Fill both sides of hopper with beads.
Close and lock hopper door. Do not allow beads to
remain in hopper, hoses or bead dispenser for an
extended period of time. Beads will absorb moisture,
bond to adjacent beads and harden.
ti14123a
S
0.5 in.
ti14410a
5.0 in.
Overfill
Line
ti22649a
ti14157a
Содержание ThermoLazer