Setup
309832D
13
Adding material to tank
Electrical wiring
The hot melt tanks use single phase, 100 to 130 VAC or
200 to 240 VAC, 50 to 60 Hz power sources, each with
earth ground for safety. The 115 VAC tanks come
equipped with a 15 amp molded plug for convenient
connection to a 115 VAC, 20 amp grounded receptacle.
The 230 VAC tanks come with a molded plug for con-
nection to an electrical circuit box or user-supplied plug.
WARNING
This equipment is designed for use with standard
adhesive and sealant such as EVAs, butyls, and
polyolefins with flash points above 450°F
(232°C). Not recommended for water curable or
solvent based adhesive. Do not use flammable
material or material not compatible with the spec-
ifications of this equipment. Failure to follow this
instruction can cause burn injury to operators
and damage to equipment.
1.
Make sure melt tank has been flushed and cleaned.
See
page 14.
If material to be added is compatible to existing
material in tank, flushing is not necessary.
2.
Fill the melt tank with the amount of adhesive mate-
rial that will be used in one day. Material should not
be higher than 1.5 in. (4 cm) from the top of the
tank.
3.
Follow the material manufacturer’s instructions for
operating temperature.