Installation
309858K
7
Unpacking
Unpack the Therm-O-Flow 20 as follows:
1.
Inspect the shipping box for damage; immediately
contact the carrier if damaged.
2.
Open the box and inspect the contents for loose or
damaged parts.
3.
Compare the packing slip against items in the box.
Report problems immediately.
4.
Store the box and packing materials to reuse if the
equipment needs to be repackaged and shipped.
Typical Installation
The typical installation drawing, F
. 1, is only a guide
for selecting and installing system components and
accessories. Contact your Graco distributor or Graco
Technical Assistance for help in designing a system to
suit your needs.
See Accessories section, page 57, for wiper rings and
other accessories.
Accessories and Modules
Before you install the system, familiarize yourself with
the parts discussed below. Refer to F
. 1.
Air and Fluid Hoses
Make sure air and fluid hoses are properly sized for your
system. Use only electrically conductive air and fluid
hoses.
Air Line Modules
4-Regulator Air Control Module (246587)
This module includes the following components:
•
Bleed-type Master Air Valve (B): for shutting off
and locking out the air supply from the entire supply
unit.
•
Pump Bleed-type Master Air Valve (C): is installed
so the valve is easily accessible and located down-
stream from the air regulator. It can be used for a
safety lockout.
•
Ram Air Regulators (N): separate air regulators to
control the ram up and down air pressures.
•
Pump Air Supply Hose (H): connects pump air
regulator to the air motor.
•
Follower Blow-off Valve Regulator (L): controls
air pressure to the follower blow-off valve.
•
Air Filter (A) and Lubricator (P): conditions air to
the ram and pump. Pump air regulator (D) is part of
this assembly. An air line tube connects the ram air
to the ram air control module.
•
Pump Air Regulator (D): adjusts air pressure to
control pump speed and outlet pressure (located on
the air control panel).
•
Automatic Depressurization Valve (Q): exhausts
air from the system at shut off. The built-in timer
delays start up to allow material to heat thoroughly.
WARNING
The bleed-type master air valve (C) is required to
relieve air trapped between this valve and the pump
after the pump air regulator is closed. Read warnings,
page 4.
Содержание Therm-O-Flow 20
Страница 43: ...Parts 309858K 43...
Страница 48: ...Electrical Schematic 48 309858K Electrical Schematic Part No 617300...
Страница 50: ...Electrical Schematic 50 309858K Part No 617484...
Страница 52: ...Electrical Schematic 52 309858K Part No 617485...
Страница 54: ...Electrical Schematic 54 309858K Part No 617349...
Страница 61: ...Dimensions 309858K 61 15 1 Pump President Air Motor Ram 52 1 in 1323 mm 75 in 1905 mm...
Страница 62: ...Dimensions 62 309858K...