Installation
10
309858K
Check Resistance
.
Supply Unit
Have a qualified electrician check resistance between
each supply unit component and true earth ground. The
resistance must be less than 0.25 ohms. If the resis-
tance is greater than 0.25 ohms, a different ground site
may be required. Do not operate the system until the
problem is corrected.
Sensor
.
The supply unit includes either three or four heat sen-
sors and controllers for each heated zone. To check
sensor resistance:
1.
Make sure the power is off and the disconnect
switch is turned to OFF.
2.
Check electrical resistance of the components at
ambient room temperature 63
°
-77
°
F (17°-25° C).
Refer to Electrical Schematic for your electrical
control, pages 48-55.
3.
Replace any parts whose resistance readings do
not comply with the ranges in the chart below.
3-Zone RTD Sensors
4-Zone RTD Sensors
Heater
.
To check heater resistance:
1.
Make sure the power is off and the disconnect
switch is set to OFF.
2.
Check electrical resistance checks of the compo-
nents at ambient room temperature (63
°
-77
°
F).
Refer to Electrical Schematic for your electrical
control, pages 48-55.
3.
Replace any parts whose resistance readings do
not comply with the ranges in the chart below.
Heaters for 3-Zone Control Panels
WARNING
The system must be properly grounded. See Ground-
ing, page 8.
WARNING
•
Read warnings, page 4.
•
Do not open electrical control panel unless you
are a trained professional.
•
Make sure power is shut off to the control panel.
•
Make sure main disconnect is OFF.
Zone Component
Terminals
Value Range
1
Follower
1311, 1321 108 ± 2% ohms
2
Dispense Hose
1531, 1541 108 ± 2% ohms
3
Dispense Gun
1601, 1611 108 ± 2% ohms
Zone Component
Terminals
Value Range
1
Follower
1311, 1321 108 ± 2% ohms
2
Dispense Hose 1531, 1541 108 ± 2% ohms
3
Dispense Gun
1601, 1611 108 ± 2% ohms
4
Pump
1381, 1391 108 ± 2% ohms
WARNING
•
Read warnings, page 4.
•
Make sure main disconnect is OFF.
Zone
Component
Terminals
Value Range
1
Follower
2L1, 2L2
98-127 ohms
2L2, 2L1
2
Dispense
Hose
1532, 1551
See Technical
Data supplied
with hose
3
Dispense
Gun
1602, 1621
See Technical
Data supplied
with gun
Содержание Therm-O-Flow 20
Страница 43: ...Parts 309858K 43...
Страница 48: ...Electrical Schematic 48 309858K Electrical Schematic Part No 617300...
Страница 50: ...Electrical Schematic 50 309858K Part No 617484...
Страница 52: ...Electrical Schematic 52 309858K Part No 617485...
Страница 54: ...Electrical Schematic 54 309858K Part No 617349...
Страница 61: ...Dimensions 309858K 61 15 1 Pump President Air Motor Ram 52 1 in 1323 mm 75 in 1905 mm...
Страница 62: ...Dimensions 62 309858K...