C
A
Fig. 3
F
B
X
A
G
Y
C
X
E
Y
H
G
J
K
E
D
X
D
cup-over option
(see manual 309205)
cup setup for spray gun
System 4900
t
Turbine
2
1
/
2
-gallon remote pressure pot
to
compressor/
cart
remote pressure pot setup for spray gun
Z
Y
J
K
H
G
F
4958C
to
compressor
2-quart remote pressure pot
ti7064a
309246 7
Setup
Connect the Fluid and Air Supply
See Fig. 3
The System ProCart
provides the air supply for
the remote pressure pot.
The circled letters in Fig. 3 indicate hose line
connections.
1.
Connect gun air supply hose (A) between turbine
air outlet (B) and gun air inlet (C). DO NOT use
wrench to tighten connections; hand tighten only.
The System 4900
turbine uses a quick connector
at outlet (B). A wrench is not required for hose
connection.
2.
If using a spray gun cup (D):
connect the cup to the gun fluid inlet (E).
If using accessory remote pressure pot (F):
connect fluid supply hose (G) between remote
pressure pot fluid outlet (H) and gun fluid inlet (E).
Connect pressure pot air hose (J) between
pressure pot air regulator inlet (K) and the
compressor/cart air outlet.
Connect to Electric Supply
Plug turbine power cord into grounded outlet.
NOTE: Extension cord must be 3-wire, 12 AWG, 50 ft
(15 m) or shorter.
Содержание System 3800