309246 13
Troubleshooting
PROBLEM
CAUSE
SOLUTION
No fluid delivery
No material, no remote
container pressurization, hose
or pickup tube clogged
Check container for material.
Check for leaks at the container gasket (2-quart
pressure pot cover or 2
1
/
2
-gallon pressure pot wing
nuts). Tighten wing nuts if loose.
Check for air flow from male quick disconnect at
compressor outlet (should be approx. 1/4 CFM).
Turn pressure regulator clockwise. Look for pressure
on gauge. (If no pressure on gauge, check air line and
fittings).
Check hole in 2
1
/
2
-gallon pressure pot cover under
regulator or in 2-quart pressure pot cover at needle
valve. Clean if necessary.
Check for obstructions.
Check if fluid pickup tube is unplugged. Tighten.
Blow out and clear material hose.
Compressor not
starting
Cold weather operation
See System ProCart
t
Cold Weather Operation on
page 9.
Turbine not starting
No power
Check outlet for power. Cycle red rocker switch.
Check that correct IEC (modular) cord is used and
plugged in.
Check circuit breaker(38). Push to reset.
Poor atomization
Dirty filter
Clean filter.
Extension cord too long
Extension cord must be 3-wire, 12 AWG, 50 ft (15 m)
or shorter.
Hose too long
Replace with shorter hose.
Circuit breaker trips
Filter clogged
Clean filter and replace as necessary.
High ambient temperature
Move turbine to cooler area.
Excessive brush wear
Remove cover and turbine, and check for free motor
rotation and for brush wear. Replace motor brushes if
necessary.
Excessive current draw
Return to authorized service center.
Содержание System 3800
Страница 12: ...12 309246 Notes ...