309246 9
Setup
Prepare Surface to be Sprayed
To get proper adhesion, make sure surface is
completely clean.
Operating System HVLP Turbine Sprayer
WARNING
Sparks can be expected in the normal operation of
the turbine motor. These sparks can ignite fumes
from flammable liquids, dust particles, and other
flammable substances in the spray area. This can
cause serious injury and property damage. Be sure
to follow the precautions below:
When flammable liquid is sprayed or used for
flushing or cleaning equipment, the turbine must
be placed at least 20 feet (6.1 m) away from
areas where hazardous concentrations of
flammable vapors are likely to occur.
Use additional air hose if necessary to ensure
that the turbine is operated in a clean, dry, well
ventilated area.
Never place the turbine inside a spray booth!
Use this equipment outdoors or in extremely
well ventilated areas.
Avoid all ignition sources such as: static elec-
tricity from plastic drop cloths, open flames like
pilot lights, hot objects like cigarettes, arcs from
connecting or disconnecting power cords, and
turning light switches on and off. Extinguish or
remove all sources of ignition.
1.
Turn turbine ON a few minutes before spraying to
allow warm-up.
NOTE: When the turbine is not in use for an extended
period of time, turn it off. The turbine does not shut off
automatically.
2.
Be sure turbine filter is clean before operating. See
page 11 to check and clean filter.
NOTE: To adjust the spray gun pattern, see the
HVLP–Turbine Gun manual 309205.
System ProCart
t
Cold Weather Operation
The System ProCart
uses a diaphragm compressor.
A new diaphragm may be stiff in cold weather. If cold
enough, the diaphragm is too stiff to allow the
compressor motor to start (the unit hums). If this
occurs, follow these steps:
1.
Turn turbine and compressor OFF.
2.
Unplug turbine from power source.
3.
Pinch and remove filter by hand. Clean or replace
if dirty.
4.
Hand spin cooling fan on compressor for a few
revolutions.
5.
Reinstall filter.
6.
Plug in turbine.
7.
Turn turbine and compressor ON. If necessary,
repeat procedure.
Содержание System 3800