Setup
309551C
17
3.
Connect electrical cord
Power cord is not supplied. See T
Table 2: Power Cord Requirements
Part No.
Model
Cord Specification
AWG (mm
2
)
246024
E-XP1
6 (13.3), 2 wire + ground
246025
E-20
8 (8.4), 2 wire + ground
246026
E-30
6 (13.3), 2 wire + ground
246028
E-XP2
4 (21.2), 2 wire + ground
246029
E-XP1
10 (5.3), 4 wire + ground
246030
E-20
10 (5.3), 4 wire + ground
246031
E-30
10 (5.3), 4 wire + ground
246032
E-XP2
10 (5.3), 4 wire + ground
246033
E-XP1
8 (8.4), 3 wire + ground
246034
E-20
10 (5.3), 3 wire + ground
246035
E-30
8 (8.4), 3 wire + ground
246036
E-XP2
6 (13.3), 3 wire + ground
WARNING
Read warnings, page 5.
a.
230V, 1 phase:
Using 5/32 or 4 mm hex
allen wrench, connect two power leads
to L1 and L2. Connect green to ground
(GND).
L1
L2
GND
TI2515A
b.
230V, 3 phase:
Using 5/32 or 4 mm hex
allen wrench, connect three power
leads to L1, L2, and L3. Connect green
to ground (GND).
c.
380V, 3 phase:
Using 5/32 or 4 mm hex
allen wrench, connect three power
leads to L1, L2, and L3. Connect neutral
to N. Connect green to ground (GND).
L1
L2
GND
TI3248A
L3
L1
L2
GND
TI2725A
L3
N