Setup
Selecting Dispensing Options
This is the procedure for setting or changing the resettable total, units of measurement, calibration factor, auto
preset amount, and shut-off default amount:
1.
If the display is asleep, wake it up by pressing the Manual/Reset or Auto/Reset button.
2.
To enter the dispensing options menus from any mode, press and hold the Manual/Reset and Auto/Reset
buttons simultaneously for four seconds.
The first menu is the Resettable Total menu, which is described in the first subsection below. You can advance
through the menus by pressing the Auto/Reset button. You will know which menu you are in, because a menu
indicator will be blinking in the display. The value that is displayed when you leave each menu and advance to
the next is the value that gets stored.
Resettable Total
In this menu, you can reset the resettable total to zero
or leave it unchanged. The resettable total accumu-
lates until the next time it is manually reset.
1.
If you have not already entered the dispensing
options menus, do steps 1 and 2 in Selecting
Dispensing Options above.
2.
With R–TOTAL blinking and the current resettable
total displayed, as shown below, do ONE of the
following two options:
D
Press the Manual/Reset button.
The resettable total is set to zero, and 0 GAL or 0
LITERS is displayed.
You can press the Manual/Reset button again to toggle
between zero and the previously displayed resettable
total. To lock in the displayed value and advance to
the Units of Measurement menu, press the Auto/Reset
button.
OR
D
Press the Auto/Reset button.
The currently displayed value is stored, and the display
advances to the Units of Measurement menu.
R-TOTAL
GAL
06044A
! CAUTION
To prevent overfills and spills
Maximum Working Pressure 7 MPa (70 bar, 1000 PSI)
D
Do not obstruct the trigger
D
Do not leave unattended
D
Do not operate below 32
_
F (0
_
C)
D
Read instruction manual
Units of Measurement
In this menu, you can set the units of measurement to
quarts, gallons, pints, or liters.
1.
If you have not already entered the dispensing
options menus, do steps 1 and 2 in Selecting
Dispensing Options above.
2.
Press the Auto/Reset button repeatedly until QTS,
GAL, LITERS, or PTS blinks to indicate that you
are in the Units-of Measurement menu.
3.
With QTS, GAL, LITERS, or PTS blinking, as
shown below, do ONE of the following two options:
D
Press the Manual/Reset button.
Each time you press the Manual/Reset button, the
display scrolls to the next unit of measurement. To
lock in the new unit of measurement and advance to
the Calibration Factor menu, press the Auto/Reset
button.
OR
D
Press the Auto/Reset button.
The displayed unit of measurement is retained, and
the display advances to the Calibration Factor menu.
GAL