Technical Data

Flow range*

0.26 to 5 gpm (1 to 18.9 lpm)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Operating pressure range

45 to 1000 psi (0.29 to 7 MPa, 2.9 to 69 bar)

. . . . . . . . . . . . . . . . . . . . . . . . 

Weight

3 lb (1.36 kg)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Units of measurement

factory-set in quarts or liters

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

maximum totalizer amount = 99999 gallons or liters

maximum recorded dispensed volume = 999.99 units

maximum preset volume = 99.9 units

Inlet

1/2 npt

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Outlet

3/8 npt

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Operating temperature range

32

_

 F to 120

_

 F  (0

_

 C to 49

_

 C)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Storage temperature range

–30

_

 F to 120

_

 F  (–34

_

 C to 49

_

 C)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Battery**

standard 9 volt alkaline

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Expected battery life in typical shop environment

6 months

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Wetted parts

zinc, stainless steel #304, LCP,

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

carbon steel, polyurethane, nitrile rubber

Fluid compatibility

lubricating oils, antifreeze mixtures

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Meter valve assembly pressure loss
at 1.5 gpm (5.7 lpm) with 30-weight oil at 70

_

 F (21

_

 C)

17 psi (117 kPa, 1.2 bar)

. . . . . . . . . . . . . . . 

Accuracy

{

+/–  0.5 percent

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Repeatability

}

+/–  0.15 percent

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

*

Tested in No. 10 motor oil.  Flow rates vary with fluid pressure and viscosity.

** Battery required to meet safety approvals:  Duracell

R

 MN1604 or Eveready

R

 EN22, 522

{

At 2.5 gpm (9.5 lpm), at 70

_

 F (21

_

 C), with 10-weight oil, and 1 gallon dispensed.  May require

calibration;  out-of-box accuracy is +/– 1.25 percent.

}

At 2.5 gpm (9.5 lpm), at 70

_

 F (21

_

 C), with 10-weight oil, and 1 gallon dispensed.

Duracell

R

 is a registered trademark of Duracell Inc.

Panasonic

R

 is a registered trademark of Panasonic Industrial Co.

Содержание PM5 238511

Страница 1: ...E3834454C2 D382 500 1025804 6 357 300 ZL97102971 7 6 047 906 187760 77664 13742 309377E D This dispense valve is designed to dispense petroleum based lubricants and antifreeze only Do not dispense win...

Страница 2: ...amaged parts immediately D Do not exceed the maximum working pressure of the lowest rated system component See the Technical Data on page 20 for the maximum working pressure of this component D Use fl...

Страница 3: ...rounding on page 6 D If there is any static sparking or you feel an electric shock while using this equipment stop dispensing immediately Do not use the equipment until you identify and correct the pr...

Страница 4: ...ispense valve The typical installation shown in Fig 1 is only a guide The components shown are typical however it is not a complete system design Contact your Graco distribu tor for assistance in desi...

Страница 5: ...ground is maintained Installation Procedure If this is a new installation or if the fluid in the lines is contaminated flush the lines before you install the metered valve Contaminated lines could cau...

Страница 6: ...material 12 Open all dispense position shut off valves and start the pump to pressurize the system See the Operation section for proper operation of meter 13 To ensure dispensing accuracy purge all a...

Страница 7: ...in the options menu The display comes awake from sleep mode when you press the Manual Reset or Auto Reset button but not when you squeeze the trigger to dispense fluid The unit does keep track of the...

Страница 8: ...between zero and the previously displayed resettable total To lock in the displayed value and advance to the Units of Measurement menu press the Auto Reset button OR D Press the Auto Reset button The...

Страница 9: ...lpm 3b Press the Auto Reset button to store the new calibration factor and advance to the Auto Preset Amount menu Auto Preset Amount In this menu you can specify an amount to be dis played when you e...

Страница 10: ...isplayed as shown below do ONE of the following two options D Enter a new shut off default amount by press ing the 10 button to change the 10s digit the 1 0 button to change the 1s digit and the 0 1 b...

Страница 11: ...ure 7 MPa 70 bar 1000 PSI D Do not obstruct the trigger D Do not leave unattended D Do not operate below 32_ F 0_ C D Read instruction manual QTS Dispensing Fluid in Manual Mode 1 Press the Manual Res...

Страница 12: ...o continue dispensing after the trigger unlocks at the preset dispense amount squeeze the trigger and the dispensed amount resumes counting in the Manual dispense mode until you release the trig ger N...

Страница 13: ...pense mode has not been selected Replace the battery See Replacing the Battery on page 16 Replace the electronic control clamshell Select a dispense mode by pressing the Manual Reset button or the Aut...

Страница 14: ...the two causes of this problem A new nozzle will not correct a fluid leak caused by a faulty valve Automatic nozzle 5b 6b or 7b has a damaged seal Valve 16 has damaged or obstructed seals Replace the...

Страница 15: ...line Err 2 Switch Error Error occurred with pick up in internal gear or Unit was dropped or unit encoun tered excessive vibration during shipping Ensure that your flow rate is not higher than 5 gpm Fo...

Страница 16: ...the battery press the Manual Reset button remove the impact guard 28 remove the battery cover 2 and put in a new battery Replacing the Filter The filter 25 is replaceable To replace the filter do the...

Страница 17: ...he valve seat into the meter housing and torque to 140 to 150 in lb 16 to 17 N m NOTE Take care that the spring 16a does not get pinched when you install the valve stem assembly 16 into the meter hous...

Страница 18: ...le 3 8 in coupled 1 6b 239829 NOZZLE automatic 1 6c 113419 NUT seal 3 8 in 18 NPT 1 6d 155699 ELBOW street 1 7 239950 NOZZLE ASSEMBLY For Model 238515 includes 7a through 7d 1 7a 191038 TUBE 15_ bend...

Страница 19: ...y lubricant when reassembling 8 6b 5a 5c 4 4 Torque to 20 to 25 ft lb 27 to 34 N m 7c 7a 7d solenoid not available for sale 27 16 2 3 6d 7c 16a 16b 16c 16d 16e 28 These parts are included in Valve Rep...

Страница 20: ...parts zinc stainless steel 304 LCP carbon steel polyurethane nitrile rubber Fluid compatibility lubricating oils antifreeze mixtures Meter valve assembly pressure loss at 1 5 gpm 5 7 lpm with 30 weigh...

Страница 21: ...21 309377 Dimensional Drawing A 14 0 in 356 mm outlet to end of swivel cover B C A B C 3 75 in 95 mm widest cross section including impact guard 3 10 in 79 mm keypad to bottom of impact guard TI0327...

Страница 22: ...ole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales inj...

Отзывы: