Appendix A - HMI Screens Overview
3A2152B
95
1. BASE/INHIBITOR/CATALYST/COLOR/MIXED Cur-
rent Pressure (PSI) readout: This is the actual
pressure in the pumps. If the pump is in the reload
position, the readout shows the pressure of the
material being pumped into the pump. If the pump is
dispensing, the readout shows the pressure of the
material being pumped to the stack. The MIXED
pressure reading is the value between the mixer
outlet and the inlet to the screw.
2. BASE/INHIBITOR/CATALYST/COLOR/MIXED high
limit: This is the pressure that will shut the machine
down if reached.
3. BASE/INHIBITOR/CATALYST/COLOR/MIXED low
limit: This is the pressure that will shut the machine
down if the pressure dips below. This is useful to
shut down the system is a pump runs out of material
and the component isn't being added to the mix. To
ignore the low level, enter zero.
4. ENABLE/DISABLE PRESSURE SHUTDOWN push
buttons and indicator. Push the Enable Pressure
Shutdown button to enable the shutdown on a pres-
sure fault.
NOTE:
This is the default value. The indicator below the
push buttons will read “ENABLED”. To disable the shut-
down, push the Disable Pressure Shutdown button. It is
recommended to leave this feature enabled. Check to
see if it only looks at the low when dispensing.
5. ENABLE/DISABLE PRESSURE ALARM push but-
tons and indicator. Push the Enable Pressure Alarm
button to enable the alarm on a pressure fault.
NOTE:
This is the default value. The indicator below the
push buttons will read “ENABLED”. To disable the
alarm, push the Disable Pressure Alarm button. It is rec-
ommended to leave this feature enabled. This is used to
keep running on a pressure fault, however the user will
get an alarm signal that the pressure went over or under
the specified values. When the pressure shut down is
enabled, the alarm is also enabled.
6. CLEAR PRESSURE FAULT push button. In the
event of a pressure shutdown fault, the system will
not run again until the pressure is brought into the
limits and the Clear Pressure Fault push button is
pressed.
Содержание LSR Select
Страница 7: ...Important Two Component Material Information 3A2152B 7...
Страница 50: ...Parts 50 3A2152B Base Pump Wet Section 24L880 ti18115a 201 202...
Страница 54: ...Parts 54 3A2152B Base Pump Inlet Outlet Valves 24L977 ti18117a 405 407 407 403 408 402 404 409 406 401...
Страница 60: ...Parts 60 3A2152B Valve Stack 24L893 ti18160a 704 706 708 703 702 701 705 707 709 712 711 710...
Страница 83: ...Control Schematics 24L890 3A2152B 83...
Страница 90: ...Appendix A HMI Screens Overview 90 3A2152B Drive Valve Control Screen Standard Drive Valve Control Screen...
Страница 93: ...Appendix A HMI Screens Overview 3A2152B 93...
Страница 111: ...Accessories 3A2152B 111...