Troubleshooting
3A2152B
31
E04
Motor Overtemp Fault
(Motor Overtemp)
Motor thermal switch
tripped
High ambient motor tem-
perature and/or exces-
sive current
•
Operate within (not above) the
continuous torque rating for the
ambient temperature 40 °C (104
°F) maximum.
• Lower ambient temperature,
increase motor cooling.
Motor wiring error.
Check motor wiring at MF
connector on the IAM/AM.
Incorrect motor selec-
tion.
Verify the proper motor has
been selected.
E05
Drive Overcurrent
Fault
(Power Fault)
Self-protection of the
Intelligent Power Mod-
ule (IPM) is indicating a
major power related fault
condition
Motor cables shorted.
Verify continuity of motor
power cable and connector.
Motor winding shorted
internally.
Disconnect motor power
cables from the motor. If the
motor is difficult to turn by
hand, it may need to be
replaced.
Kinetix 2000 drive tem-
perature too high.
•
Check for clogged vents or
defective fan.
• Make sure cooling is not
restricted by insufficient space
around the unit.
Operation above contin-
uous power rating and/or
product environmental
ratings.
•
Verify ambient temperature is
not too high.
• Operate within the continuous
power rating.
• Reduce acceleration rates.
Kinetix 2000drive has a
short circuit, overcur-
rent, or failed compo-
nent.
Remove all power and motor
connections, and preform a
continuity check from the dc
bus to the U, V, and W motor
outputs. If a continuity exists,
check for wire fibers between
terminals, or send drive in for
repair.
E06
HardOvertravel Fault
(+/- Hard Overtravel)
Axis moved beyond the
physical travel limits in
the positive/negative
direction
Dedicated overtravel
input is inactive.
•
Check wiring.
• Verify motion profile.
• Verify axis configuration in soft-
ware.
E07
MotFeedbackFault
(Motor Feedback Loss)
The feedback wiring is
open, shorted, or miss-
ing.
•
Check motor encoder wiring.
• Run Hookup test in RSLogix
5000 software.
Error
Code
Fault Message
RSLogix (HIM)
Problem or Symptom
Potential Cause
Possible Resolution
Содержание LSR Select
Страница 7: ...Important Two Component Material Information 3A2152B 7...
Страница 50: ...Parts 50 3A2152B Base Pump Wet Section 24L880 ti18115a 201 202...
Страница 54: ...Parts 54 3A2152B Base Pump Inlet Outlet Valves 24L977 ti18117a 405 407 407 403 408 402 404 409 406 401...
Страница 60: ...Parts 60 3A2152B Valve Stack 24L893 ti18160a 704 706 708 703 702 701 705 707 709 712 711 710...
Страница 83: ...Control Schematics 24L890 3A2152B 83...
Страница 90: ...Appendix A HMI Screens Overview 90 3A2152B Drive Valve Control Screen Standard Drive Valve Control Screen...
Страница 93: ...Appendix A HMI Screens Overview 3A2152B 93...
Страница 111: ...Accessories 3A2152B 111...