Operation
22
3A2152B
g. Set the INHIBITOR PERCENT OF MIX to 6%.
h. Set the CATALYST PERCENT OF MIX to 0%
or 1%.
i.
Set the COLOR PERCENT OF MIX to the
desired percent.
j.
Verify the TOTAL PERCENT (REF) is 100%
k. Press and hold the footswitch down. All pumps
will start to dispense.
l.
When the base pump hits the end travel
released the footswitch; all pumps will reload.
m. When the pumps are reloaded, repeat this
about fifteen times to verify the volume of the
mixer has color through the mixer and the mate-
rial coming out is air-free.